A Program
Menu Features: Batch Parameters
The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION
Program Items Factory set Default Programming Range Increments
Notes
A1.10
Batch Volume
3.8 L
1 gal
0.95 to 4.75L
0.25 to 1.25 gal
0.05L
0.01G
Unit software is in L;
converts to gallon
A1.20
Brew Time
4:00 minutes
2:00 – 12:00
0.30
Default total brew time is
5:30 minutes
A1.30
Prewet Perc.
0%
0.00 – 25.0%
1%
Percentage of total brew
volume
A1.40
Prewet Delay
(Pause after prewet
completes)
0% [1:00 Min]
[0:10 – 5:00]
1:00 min
The time between
prewetting and start of
brew cycle.
This feature appears
ONLY if Prewet >0:00
A1.60
This is a
Safety
Feature
Drip Delay
1:30 mm:ss
0:30 – 6:00 Min.
Time that brew basket
remains locked during final
drip-out
Drip delay remains “ON”
for 1:30 minutes if STOP
is pressed during brew†
A2.00
BATCH
ENABLED
YES
(Active)
Middle and Bottom
batches A2,3,5,6
Batch on or
off
Batches may be
individually enabled,
rewritten or deactivated
A2.10
Batch Volume
2.90L
0.75gal
0.95 to 4.75L
0.25 to 1.25 gal
0.05L
0.01G
Unit software is in L;
converts to gallon
A2.20
Brew Time
3:30 minutes
2:00 – 12:00
0.30
Default total brew time is
5:30 minutes
A2.30
Prewet Perc.
0%
0.00 – 25.0%
1%
Percentage of total brew
volume
A2.40
Prewet Delay
(Brew pause after
prewet completes)
0% [1:00 Min]
[0:10 – 5:00]
1:00 min
The time between
prewetting and start of
brew cycle.
This feature appears
ONLY if Prewet >0:00
A2.60
Safety
Feature
Drip Delay
1:30 mm:ss
0:30 – 6:00 Min.
Time that brew basket
remains locked during final
drip-out
A30
Batch Enabled
A30 YES
-
NO
+
NO-inactive
(defaults to recipe
A20 if activated)
Middle and Bottom
batches A2,A3
Batch
on or off
Batches may be
individually enabled,
rewritten or deactivated
Batch
Copy
Copy From Batch A90
A90 1 (1-6)
Copy To Batch?
A91
A91.1 (1-6)
Single Topmost Batch cannot be disabled. TWIN Topmost Batch LEFT & RIGHT cannot be disabled.
Middle and bottom batches may be disabled for single and twin brewer (CBS-1231 and CBS-1232 )
† DRIP DELAY
will not activate when STOP is pressed within 5 seconds of starting a brew time
.
RECIPE Location map
Viewing and changing settings for the brew
recipes is from the “A” screens with the controls in
PROGRAMMING.
The uppermost button positions are permanent
and will not display programming step A_0. The
table above shows in position A20 that a button
position can be made
active or inactive
.
Position A1 does not display this step
DISPLAY
DISPLAY
STOP
STOP
BATCH
A1
(permanent)
BATCH
A4
(permanent)
BATCH
A2
(enabled by factory)
BATCH
A5
(enabled by factory)
BATCH
A3
(disabled by factory)
BATCH
A6
(disabled by factory)
STOP
Single Side Models
CBS-1231
Plus
STOP
STOP
Dual Side Models
CBS-1232
Plus