Fetco E1231IN-1B123-PM000 Users Manual And Operator Instructions Download Page 5

Go to fetco.com for the latest versions of all information         

Page 5

      

User Guide & Operator instructions

   

P211

e0

November 2021

 

Programing Menu Layout

 

 

 

 

 

A10 to A70 

 

B10-B40 

 

C10-C50 

 

D10-D90 

 

E10-E70 

 

F10-F120 

 

G1-G15 

 

H10-H11 

 

 

Batch Parameters 

 

General Settings 

 

Service Inputs 

 

Service Outputs 

 

Calibration 

 

Service Menu 

 

Counters 

 

Exit and Save 

 

 

 

 

 

 

 

 

 

 

A11 

Brew Volume 

B1 

Tank Temperature 

C1 

LLC Probe 

D1 

Heater SSR 

E1 

Ready Temp. Offset 

F1 

Firmware Ver. 

G1 

Filter Used 

H1 

Save Changes 

 

 

 

 

 

 

 

 

 

 

A12 

Brew Time 

B2 

Brew at Temp 

C2 

Basket Sensor 

D2 

Fill Valve 

E2 

LLC Sensitivity 

F2 

Bootloader Ver. 

G2 

Filter Life 

H2 

EXIT? 

 

 

 

 

 

 

 

 

 

 

 

A13 

Prewet Percent 

B5 

Show Tank Temp 

C4 

Tank Temperature 

D3 

Lt Brew Valve 

E3 

Slow Flow Compensate 

F3 

Select Model 

G3 

Filter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A14 

Prewet Delay 

B4 

Units of Temp 

C5 

USB Drive 

D4 

Rt Brew Valve 

E4 

Lt Brew Flow 

F4 

Option Bypass 

G4 

Counter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A16 

Drip Delay 

B6 

Units of Volume 

C6 

Keyboard Test 

D12 

LCD Brightness % 

E5 

Rt Brew Flow 

F5 

Option BB Lock 

G5 

Choose Counter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A20 

Batch (2) Enabled 

B7 

Customer Name 

 

 

D13 

LED Brightness % 

 

 

F8 

Backup to USB 

G10 

Brewer Volume 

[T]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A21 

Brew Volume 

B7 

Customers Name 

 

 

 

 

 

 

F9 

Restore from USB 

G11 

Brewer Volume 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A22 

Brew Time 

B9 

Demo Mode 

 

 

 

 

 

 

F10 

Restore Defaults 

G12 

LT Brews[T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A23 

Prewet Percent 

B10 

Eco Mode 

 

 

 

 

 

 

F11 

Error Log 

G13 

LT Brews 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A26 

Drip Delay 

B11 

Eco Idle Time 

 

 

 

 

 

 

F12 

Erase Error Log 

G14 

Rt Brews [T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A30 

Batch (3) Enabled 

B12 

Eco Idle Temp 

 

 

 

 

 

 

F13 

Service Phone# 

G15 

Rt Brews  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A90 

Copy Batch 

B13 

Filter Life 

 

 

 

 

 

 

F14 

Override Lt BBS 

 

See Page 12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A91 

Copy Batch: From 

 

 

 

 

 

 

 

 

F15 

Override Rt BBS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A92 

PASTE: To 

 

 

 

 

 

 

 

 

F16 

Override Lt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F17 

Override Rt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left and Right top and middle batches are permanent  SEE BOX on the following page for all “A” menus

 

 

The “A” menu is the most accessed menu.  It is for programming the batch volumes, brewing parameters, enabling or 

disabling brew buttons.  The “A” menu moves through the six positions(CBS-1232+) or three positions(CBS-1231+) by 

entering the menu and pressing the left stop button.  (only the left side is active for programming the CBS-1232+) 

 

The A menus [A1-3 or A1-6] correspond to batch buttons [3 or 6] on the touch panel 

Access the A menus to PROGRAM & make changes to individual menu recipes.  Menu settings can be copied  

Menu positions A1 and A4 [top position] are permanent.  Menus A2, A3, A5, A6 can be removed by operator if desired 

 

 

 

 

 

 

From A PRG screen 

Press button 1 to go 

into to the A menu 

access screens.  

Continue pressing 

button #1 to enter 

progamming for A1 

From A11 screen 

Press 

STOP

 to scroll 

to A20.  

(A1&A4 are permanent) 

From A20 screen 

Press STOP to  

scroll through the 

remaining (3 or 6) 

“A” menus.  Make 

any changes as 

required 

From A60 screen 

Scroll out to 

remaining A10-to 

A70 programming 

keys.  See SAVE & 

EXIT in previous 

table 

For single and twin 

Position of batch buttons 

for CBS-1232+  

 

The CBS-1231+ single 

position brewer has  one 

row of buttons  

 

 

 

 

  Batch Program 

  A1 

STOP 

STOP 

STOP 

  Brew Volume 

  A1.10   3.80L  +/- 

STOP 

STOP 

  Batch Enabled 

  A6.00            NO+ 

STOP 

  

(Dual model shown)

 

  Batches A1 to A6 

STOP 

STOP 

A1 

A2 

A3 

A4 

A5 

A6 

  Batch Enabled 

  A2.00           YES - 

STOP 

STOP 

Summary of Contents for E1231IN-1B123-PM000

Page 1: ...de and Operator Instructions CBS 1231 CBS 1232 Extractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1232 CBS 1232 3 0 4 0 Extractor Plus Brewers shown with 2 2 liter Air Pot sold...

Page 2: ...y Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1231 Brewer 27 3 4 in 700 mm 11 3 4 in 300 mm 20 in 520 mm 3 3 gallon 12 4 L 29 lbs 13 2 kg 55 lbs 25 0 kg 41 lbs 18 6 kg 30 x 17 x 22 76...

Page 3: ...erminal Block 1 10 9 13 0 7 7 gal 29 1 L CBS 1231PLUS 3 0 4 0 Lit er Coffee B rewers C E m odels Electrical and Output Specifications Schuko cor d and pl ug 50Hz SKU Voltage Heater C onfiguration Wire...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right top and middle batches are per...

Page 6: ...30 minutes 2 00 12 00 0 30 Default total brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...ncrements Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve Test Press b...

Page 9: ...47G 61oz 1 05 1 60Liter 0 39 0 55G 50 71 fl ounces 0 05L 0 01G 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 1 30 liters minute 0 36 gallon minute 46 ounces minute 1 10 1 65Liter 0 28 0 42G 37...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...r short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate is too low Watch for short...

Page 12: ...Volume LT Left brew valve flow through volume Gallons Liters Totalized volume through left valve CBS 1232 only G27 A Lt Brew Volume R G28 A Rt Brew Cycles LT Right brew valve operation on off Count T...

Page 13: ...en From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE User Settings will be erased and overwritten to factory default s...

Page 14: ...er such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish...

Page 15: ...possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacemen...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...1232 4 required for CBS 1231 Legs are sent from factory inside brew basket Attach legs before installing 2 Adjust dispenser locator for either 3 Liter 1 Gallon dispensing Set Dispenser Locator Shown...

Page 18: ...rts Diagram CBS 1231 Drawing 1101 00570 00 Parts CBS 1231 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 19: ...41 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 33 1 1402 00098 10 HARNESS LOW AMP CBS 1230 UL 34 1 1046 000...

Page 20: ...ts Diagrams CBS 1232 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Drawing 1101 00571 00 Parts CBS 1232 2 1 2 legs Extends to 3 5 8 Part number 1073 00016 00 3 required for CBS 1232 4 requir...

Page 21: ...023 00355 00 LOCATOR AIRPOT ADAPTER CBS 2230 29 1 1001 00408 00 COVER TOP CBS 2232 42 30 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 31 11 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 32 1...

Page 22: ...UNDERSIZED ZINC PLATED 9 1 1107 00021 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 1 11...

Page 23: ...OTH LOCKWASHER 8 10 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 10 2 1003 00140...

Page 24: ...FITTING STRAIGHT GROMMET 400 10 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 11 2 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 11 2 1107 00020 00 HEATER ASSEMBLY IMMERSION 2300W 240...

Page 25: ...02 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078 00...

Page 26: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 27: ...Go to fetco com for the latest versions of all information Page 27 User Guide Operator instructions P211e0November 2021 Wiring Diagrams SSR SSR SKU E1231US 1X117 PM001 CBS 1231 Domestic Dual Voltage...

Page 28: ...com for the latest versions of all information Page 28 User Guide Operator instructions P211e0November 2021 S S R Wiring diagram 1401 00190 10 E1231US 1A115 E1231US 1A123 E1231US 1X117 E1231IN 1B130 C...

Page 29: ...com for the latest versions of all information Page 29 User Guide Operator instructions P211e0November 2021 SSR Wiring diagram 1401 00196 10 E1232US 1B223 E1232US 1B230 E1232IN 1B223 E1232IN 1B230 CB...

Page 30: ...End of section notes N...

Reviews: