![Festool TURBO II M - 14 WP Original Operating Manual Download Page 19](http://html.mh-extra.com/html/festool/turbo-ii-m-14-wp/turbo-ii-m-14-wp_original-operating-manual_2285136019.webp)
Turbo II M
19
GB
3
Technical data
* The values mentioned are emissions values and do
not necessarily correspond to the standard of work.
In fact, there is a correlation between the emissions
and exposure values, but these cannot be used reli-
ably to determine whether further precautionary
measures are unnecessary. Factors which influence
the actual level of exposure of the workers include
features of the workspace, other sources of noise,
etc., for example the number of machines and other
neighbouring work. The permissible exposure level
may vary from country to country. Using this informa-
tion the user of the machine can make a better as-
sessment of the dangers and risks.
4
Intended use
The exhaust turbine
Turbo II M - 8 WP/ - 14 WP
– corresponds to dust class ’M’ according to IEC/
EN 60335-2-69 App. AA and is suitable for ex-
tracting hazardous dust with occupational expo-
sure limit values ≥ 0.1 mg/m³ as well as wood and
paint dust,
– designed exclusively for industrial use.
– Extracting dust with a Kst value > 200 (bar*m)/s
and/or an ignition energy < 10 mJ is not permit-
ted. Please observe local regulations.
– not suitable for extracting liquids.
Turbo II M - 8 WP/ - 14 WP ATEX
– corresponds to dust class ’M’ according to IEC/
EN 60335-2-69 App. AA and is suitable for ex-
tracting hazardous dust with occupational expo-
sure limit values ≥ 0.1 mg/m³ as well as wood and
paint dust,
– is suitable for absorbing and extracting dry, com-
bustible and conductive dust at machines and de-
vices in Zone 22,
– designed exclusively for industrial use,
– suitable up to a total dust load of 160 g/min (8WP)
and 280 g/min (14WP).
– not suitable for extracting liquids.
Conductive parts of machines, including suction
Extraction turbine
Turbo II M - 8 WP
Turbo II M - 14 WP
Power supply (input)
400 V 3~
400 V 3~
Mains frequency
50/60 Hz
50/60 Hz
Power consumption
7.5 kW
11 kW
Fuse
16 A
32 A
Compressed air supply
6 - 10 bar, not oiled
6 - 10 bar, not oiled
Max. volume flow (air)
850 m
3
/h
1230 m
3
/h
Nominal volume flow (admission rate 20 m/s)
565 m
3
/h
565 m
3
/h
Max. vacuum in normal operation
- 180 hPa
- 180 hPa
Max. vacuum in the event of a fault (e.g. power failure)
- 400 hPa
- 400 hPa
Sound pressure level as per EN 60704-1 and uncertainty K
(at 40 Hz) *
65 dB(A)
4 dB
66 dB(A)
4 dB
Filter surface area
4.8 m
2
7.2 m
2
Dimensions (LxWxH)
1045 x 805 x 1740 mm 1045 x 805 x 1740mm
Container capacity
50 l
50 l
Weight
315 kg
315 kg
Dust extraction, diameter of connection pipes
100 mm
100 mm
Protection category
IP 5x / IP 64 (ATEX)
IP 5x / IP 64 (ATEX)
Permissible ambient temperature in operation
0 - 45 °C
0 - 45 °C
Relative humidity
Max. 90%
Max. 90%
Residual dust content in circulating air
< 0.1 %
< 0.1 %
ATEX identification
CE 0637
II 3D Ex tc IIIC T135°C Dc
0°C≤Ta≤45°C X
Number of EC-Type examination
IBExU14ATEXB007 X