Connection
Plug/cable
Purpose
[X4]
Connecting cable
NEBC-S1WA9-P-1.5-N-BB-L2G4
Connection for controller
CECC-X-M1-YS
[X6]
Motor cable
Connection for servo motor con-
nection
[X9]
Plug
1)
Power supply
[X18]
Standard LAN patch cable
2)
Ethernet interface
[X40]
Plug
Interface for STO function
1) Plug for customer-provided cable
2) not included in the scope of delivery of the kit
Tab. 15 Connection and plug
Basic setting of DIP switch
The two DIP switches on the motor controller CMMP-AS must be set to a defined basic setting in this
application.
1. Set switch [S2] to the position [0].
2. Set switch [S3] to the position [0].
Power supply [X9]
•
Connect the power supply in accordance with the table
è
Force range
Power supply
Up to 4 kN
100
…
230 V AC (1 phase)
From 7 kN
230
…
480 V AC (3 phases)
Tab. 16 Power supply
Ethernet interface [X18]
The Ethernet interface is used to for the connection with the higher-order controller.
8.5
I/O interface for STO [X40]
The STO function is described in the additional documents
è
Motor controller
Design on the device
Counterplug
CMMP-AS
PHOENIX MINICOMBICON MC
1.5/8-GF-3.81 BK
PHOENIX MINICOMBICON MC
1.5/8-STF-3.81 BK
Tab. 17 Plug design [X40]
Installation
26
Festo — YJKP — 2019-01e