1. Supply the device with power.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X1] of the controller.
Power supply [X5]
–
Power supply for digital outputs.
–
Resultant current for all supplied ports:
£
5 A
Terminal
Connection
Use
X5.1
24
24 V DC
X5.2
0
0 V DC
Tab. 10 Connection, power supply for digital outputs
1. Supply the device with power.
2. Place the open cable ends in the plug provided in accordance with the table.
3. Insert the plug into the connection [X5] of the controller.
I/O interface [X2, X3, X4]
Terminal
Connection
Use
X2.0
…
X2.7
8 digital inputs
Configurable as step enabling
condition in the sequencer of
the press process: DI1
…
DI8
1)
X3.0
Start the press process
1)
Manual operating mode: plot
the reference curve
Automatic operating mode:
start the press process
X3.1
"Manual" operating mode
1)
X3.2
"Automatic B" operating
mode
1)
X3.3
Start homing
1)
X3.4
Acknowledge errors
1)
X3.5
6 digital inputs
Terminate press process
1)
2)
X4.0
…
X4.3
4 digital outputs
Configurable as output signals
in the sequencer of the press
process: DO1
…
DO4
1)
24 V DC output set by the soft-
ware as soon as certain event
occurs (position reached, force
reached).