NOTICE!
Material damage as a result of using the wrong connections.
In accordance with intended use, all unnamed connections must not be used.
Details on handling the individual components of the kit are described in separate documents
è
8.2
Electrical installation - cables
Connecting cable NEBS-M12G5-ES-...-LE5
The connecting cable connects the sensor on the electric drive with the analogue input [X19] on the
controller.
The accompanying plug must be assembled on the open cable ends.
Sensor SKDA
Controller CECC-X-M1-YS
Connection
Pin
Wire colour
1)
Use
Pin
Connection [X19]
1
BN
24 V DC
Power supply for
sensor
X19.0.1
2
WH
Not used
3
BU
Input 4
…
20 mA
Evaluation of the
sensor signal
through servo
press software
X19.0.2
4
BK
Not used
5
GY
Not used
Braided screen
Apply braided
screen in direct
proximity of con-
troller and sensor
with a large sur-
face area
1) Colour code in accordance with IEC 60757:1983-01
Tab. 3 Sensor connecting cable - analogue inputs [X19]
1. Connect connecting cable to the sensor.
2. Place the open cable ends in the plug provided in accordance with the table.
Installation
12