1. MPA pneumatic modules
1−12
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Note that MPA electronic modules may only be supplied with
power via the following supply modules:
MPA electronic module
Permitted supply modules
(type)
VMPA1−FB−EM
S
−...
VMPA2−FB−EM
S
−...
(in each case
without
elec
trical isolation)
System supply
CPX−GE−EV−
S
(M18 4−pin) or
System supply
CPX−GE−EV−
S
−7/8−
4POL
(7/8" 4−pin)
VMPA1−FB−EM
G
−...
VMPA2−FB−EM
G
−...
(in each case
with
electrical
isolation)
Valve supply modules
CPX−GE−EV−
V
.. (M18 or 7/8") or
System supply modules
CPX−GE−EV−
S
.. (M18 or 7/8")
1)
Intermediate electrical supply mod
ule (supply plate (electric) type
VMPA−FB−SP−...−V−...)
1)
If a 4−pin system supply module is used, the electrical isolation
will no longer be effective.
Tab.1/3: Permitted supply modules modules for MPA elec
tronic modules
In the case of MPA electronic modules
with
electrical isolation
type VMPA1−FB−EM
G
−... or VMPA2−FB−EM
G
−... , V
EL/SEN
and
V
VAL
are completely electrically isolated. In conjunction with
the following voltage supply modules, it is therefore possible
to switch off the valve supply voltage at all poles:
Manifold sub−base with valve supply type CPX−GE−EV−
V
..
(M18 or 7/8")
7/8" manifold sub−base with 5−pin system supply module
type CPX−GE−EV
−
S−7/8−
5POL
Intermediate electrical supply module (supply plate (elec
tric) type VMPA−FB−SP−...−V−...)
Summary of Contents for VMPA-FB-PS Series
Page 2: ......
Page 49: ...MPA pressure sensor 2 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 2 Type VMPA FB PS ...
Page 83: ...Technical appendix A 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix A ...
Page 90: ...A Technical appendix A 8 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 91: ...Index B 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix B ...
Page 92: ...B Index B 2 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 96: ...B Index B 6 Festo P BE MPA ELECTRONIC EN en 0804NH ...