Parameters of pneumatic interfaces types
CPX−GP−03−4.0, CPX−GP−CPA−... and VABA−10S6−X1
Module parameters: Monitoring the CPX module
Function no.
4828 + m * 64 + 0
m = module number (0...47)
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for each module separately. Active monitoring causes the following: The fault is:
sent to the CPX field bus node
displayed by the common module fault LED.
Bit
2
3
Monitoring
Description
Undervoltage of valves (V
VAL
)
Short circuit at the valve (SCV)
[Monitor]
[Monitor Vval]
[Monitor SCV]
Values
1 = active
0 = inactive
Presetting: bit 2: active;
bit 3: inactive
[Active]
[Inactive]
Remark
Monitoring can also be set for the complete CPX terminal
(see CPX system manual).
[...] = display in the Handheld
Tab.1/4:
Monitoring the CPX module
Summary of Contents for VMPA...-FB-EPL Series
Page 2: ......
Page 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Page 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Page 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Page 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Page 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Page 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Page 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Page 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...