VEAB-...
Festo AG & Co. KG
Postfach
73726 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Operating instructions
(Original instructions)
8058831
1701
[8058833]
Proportional pressure regulator valve VEAB-...
English
. . . . . . . . . . . . . . . . . . . . . .
For all available product documentation
è
www.festo.com/pk
1
Safety
1.1 Use for intended purpose
The VEAB-... proportional pressure regulator is intended to regulate a pressure
proportional to a specified setpoint value.
The valve is intended for use in an industrial environment.
1.2 Safety instructions
The valve may only be used in its original status without unauthorized
modifications.
Only use the valve if it is in perfect technical condition.
Comply with all applicable national and international regulations.
Comply with specified limits (
è
Take into consideration the ambient conditions at the location of use.
1.3 Training of specialized personnel
Only qualified personnel may perform installation, commissioning, maintenance
and disassembly of the valve. The specialized personnel must be familiar with the
installation and operation of electrical and pneumatic control systems.
2
Design
2.1 In-line valve
2
4
5
1
3
6
1
“Power” LED
2
Electrical connection, plug M8
3
Air port (2)
4
Compressed air port (1)
5
Exhaust air port (3)
6
Through-holes for fastening the
valve
Fig. 1
For the vacuum type (VEAB-...-D14-...), compressed air port 1
(Pos.
4
, Fig. 1) must be opened to the environment. The vacuum is
connected to port 3 (Pos.
5
, Fig. 1) and the supply air is suctioned from
the environment through port 1 (Pos.
4
è
2.2 Sub-base valve
1
2
3
3
1
“Power” LED
2
Electrical connection, plug M8
3
Through-holes for fastening the
valve to the connection plate
Fig. 2
3
Product variants
Characteristic
Type code
Description
Basic function
VEAB
Piezo proportional pressure regulator
Valve type
L
In-line valve
B
Sub-base valve
Valve function
26
2 x 2/2-way valve, normally closed
Pressure range
D14
0 … –1bar
D12
0 … 0.2bar
D7
0 … 1bar
D2
0 … 2bar
D9
0 … 6bar
Pneumatic port
F
Flange/sub-base
Q4
Push-in connector 4 mm
Setpoint specification and
actual value output
V1
Voltage variant 0 … 10V
A4
Current variant 4 … 20 mA
Nominal operating
voltage
1
24V DC
Electrical connection
R1
M8, 4-pin
Fig. 3
4
Function
A built-in pressure sensor records the pressure at the working port and compares
this value with the setpoint value. In the event of deviations between the setpoint
value and actual value, the valve regulates until the outlet pressure has reached
the setpoint value.
Fig. 4
5
Transport and storage
Store the product in a dry, UV- and corrosion-protected environment. Ensure
storage times are short.
6
Installation
6.1 Mechanical
Make sure there is sufficient space for the connecting line and tubing
connections. In this way you will prevent the connecting lines and the tubes from
being broken.
Place the valve as close to the consumer as possible. This leads to improved
control precision and shorter response times.
Mounting options of the valve:
– Through-hold mounting of the in-line valve through 3 lateral through-holes
– Mounting of the in-line valve to the H-rail using H-rail mounting VAME-P7-T
– Mounting of the in-line valve to the mounting plate VAME-P7-Y
– Mounting of the sub-base valve using the sub-base VABM-....
The mechanical installation of the valve is described in the VAME-P7-T
(H-rail) and VAME-P...-Y (mounting plate) assembly instructions
(
è
www.festo.com/sp).