Translation of the original instructions
© 2020 all rights reserved to Festo SE & Co. KG
1
About this document
1.1
Further applicable documents
All available documents for the product
è
User documentation
Name, type
Contents
H-rail mounting, VAME-P7-T
Assembly instructions
Mounting plate, VAME-P...-Y
Assembly instructions
Manifold rail, VABM-P6-15.../-P7-18...
Assembly instructions
Tab. 1 Documentation on the product
1.2
Product Labelling
–
Observe the specifications on the product.
Warning Symbol
The following warning symbol can be seen on the product:
Symbol
Meaning
If the housing is damaged (for example due to cracks), protection against dangerous
voltage is no longer guaranteed.
–
Do not start the device.
–
Immediately shut down the device.
Tab. 2 Warning Symbol
2
Safety
2.1
Safety Instructions
–
Only use the product in original status without unauthorised modifications.
–
Only use the product if it is in a perfect technical condition and it is not dam-
aged in any way.
–
Take into consideration the ambient conditions at the location of use.
–
Prior to mounting, installation and maintenance work: Switch off power sup-
ply and secure it from being switched back on.
–
When installing the product, ensure that it can only be accessed by author-
ised persons.
–
Observe additional safety instructions in chapter
è
2.2
Intended use
The proportional-pressure regulator is intended to regulate a pressure propor-
tional to a specified setpoint value.
The product is intended for use in industrial environments.
2.3
Training of skilled personnel
Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.
The specialized personnel must be familiar with the installation and operation of
electrical and pneumatic control systems.
3
Further information
–
Accessories
è
4
Service
Contact your regional Festo contact person if you have technical questions
è
5
Product overview
5.1
Functional principle
A built-in pressure sensor records the pressure at the working port and compares
this value with the setpoint value. In the event of deviations between the setpoint
value and actual value, the valve regulates until the outlet pressure has reached
the setpoint value.
Fig. 1 Pneumatic circuit symbol
5.2
Configuration
5.2.1
Product design
In-line valve
1 LED
2 M8 plug
3 Working air port (2)
Fig. 2 View from front
1 Compressed air port (1)
2 Exhaust air port (3)
3 Through-holes for mounting the
valve
Fig. 3 View from rear
Sub-base valve
1 LED
2 M8 plug
3 Through-holes (2x) for mounting
the valve on the sub-base
Fig. 4 View from front
8114190
VEAA
Proportional-pressure regulator
8114190
2020-02b
[8114192]
Instructions | Assembly, Installation, Operating
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com