4. The control panel (only type SFC−LAC−...−H2−...)
4−17
Festo P.BE−SFC−LAC−CO−EN en 0708NH
4.5.5
[Settings] [Jog mode]
You can use the arrow keys to move the drive continuously
(also possible without previous reference run). The software
end positions have no function here.
4.5.6
[Settings] [CO parameter]
Setting the field bus parameters.
[CO parameter]
Parameter
Description
[CAN Node ID]
1
Ū
127
(1
Ū
7fh)
Field bus address of the SFC−LAC.
Representation: 1 dec, 1 hex"
Ū
"127 dec, 7f hex"
[CAN Baudrate]
1000 kBd,
800 kBd,
500 kBd,
250 kBd,
125 kBd,
100kBd,
50kBd,
20kBd,
10kBd
Field bus baud rate as per settings on master.
[CAN Profile]
DS402,
FHPP
Profile with which communication between the CAN master and
the SFC−LAC is handled:
DS402: Control takes place as per DS402.
FHPP:
Control takes place as per Festo Handling and
Positioning Profile.
[CAN Volt.Supply]
intern,
extern
Power supply to the field bus node can take place internally",
i.e. via the logic voltage supply of the SFC−LAC, or externally"
via the field bus (via optocoupler electrically isolated from the
logic voltage of the SFC−LAC), see section 3.6.
Tab.4/6:
Menu [Settings] [CAN parameter]
The settings in the menu [CAN parameter] are saved directly
and permanently (including in the event of a power failure) in
the EEPROM after confirmation with OK <Enter>.
Summary of Contents for SFC-LAC CO Series
Page 4: ...Contents and general instructions II Festo P BE SFC LAC CO EN en 0708NH...
Page 10: ...Contents and general instructions VIII Festo P BE SFC LAC CO EN en 0708NH...
Page 21: ...System summary 1 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 1...
Page 41: ...Fitting 2 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 2...
Page 47: ...Installation 3 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 3...
Page 71: ...The control panel only type SFC LAC H2 4 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 4...
Page 91: ...Commissioning 5 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 5...
Page 171: ...Diagnosis and fault display 6 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 6...
Page 188: ...6 Diagnosis and fault display 6 18 Festo P BE SFC LAC CO EN en 0708NH...
Page 189: ...Technical appendix A 1 Festo P BE SFC LAC CO EN en 0708NH Appendix A...
Page 195: ...Parametrizing in accordance with FHPP FPC B 1 Festo P BE SFC LAC CO EN en 0708NH Appendix B...
Page 272: ...B Parametrizing in accordance with FHPP FPC B 78 Festo P BE SFC LAC CO EN en 0708NH...
Page 273: ...Object directory DS204 and CI C 1 Festo P BE SFC LAC CO EN en 0708NH Appendix C...
Page 319: ...Index D 1 Festo P BE SFC LAC CO EN en 0708NH Appendix D...
Page 320: ...D Index D 2 Festo P BE SFC LAC CO EN en 0708NH Contents D Index D 1...