4. The control panel (only type SFC−LAC−...−H2−...)
4−12
Festo P.BE−SFC−LAC−CO−EN en 0708NH
For starting positioning travel or reference travel:
·
Note the instructions in section 5.2.10 (test run) or 5.2.3
to 5.2.5 (reference travel).
1. Select the menu [Positioning] in the main menu.
2. Select a menu command:
[Positioning]
Description
Note
[Homing]
Reference travel as per the set
homing method.
Setting the parameters: see
[Settings] [Homing paramet.]
[Move posit. set]
Positioning run for testing a
particular position record in the
position record table.
Parametrizing and referencing must
have been completed.
[Demo posit. tab]
Positioning cycle (continuous loop)
for testing all position sets in the
position set table.
Parametrizing and referencing must
have been completed.
There must be at least two position
records in the memory.
Tab.4/4:
[Positioning] menu
During the positioning run the following information is
displayed:
the active position record, Pos...
the target position, x
t
the positioning speed, v
the current position, x
a
EMERG.
STOP
With <Menu> you can interrupt the positioning
procedure (
>
Error mode EMERG.STOP).
Menu
DEMO
STOP
With <Enter> you can interrupt the positioning
cycle [Demo posit tab]. The current positio
ning set will be executed before the axis
stops. If you restart, the run will begin with
position record 1.
Enter
}
Positioning
Homing
Move posit. set
Demo posit. tab
...
Pos 1
X
t
= 100.00 mm
v = 20 mm/s
X
a
= 90.00 mm
EMERG.STOP<Menu>
Summary of Contents for SFC-LAC CO Series
Page 4: ...Contents and general instructions II Festo P BE SFC LAC CO EN en 0708NH...
Page 10: ...Contents and general instructions VIII Festo P BE SFC LAC CO EN en 0708NH...
Page 21: ...System summary 1 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 1...
Page 41: ...Fitting 2 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 2...
Page 47: ...Installation 3 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 3...
Page 71: ...The control panel only type SFC LAC H2 4 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 4...
Page 91: ...Commissioning 5 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 5...
Page 171: ...Diagnosis and fault display 6 1 Festo P BE SFC LAC CO EN en 0708NH Chapter 6...
Page 188: ...6 Diagnosis and fault display 6 18 Festo P BE SFC LAC CO EN en 0708NH...
Page 189: ...Technical appendix A 1 Festo P BE SFC LAC CO EN en 0708NH Appendix A...
Page 195: ...Parametrizing in accordance with FHPP FPC B 1 Festo P BE SFC LAC CO EN en 0708NH Appendix B...
Page 272: ...B Parametrizing in accordance with FHPP FPC B 78 Festo P BE SFC LAC CO EN en 0708NH...
Page 273: ...Object directory DS204 and CI C 1 Festo P BE SFC LAC CO EN en 0708NH Appendix C...
Page 319: ...Index D 1 Festo P BE SFC LAC CO EN en 0708NH Appendix D...
Page 320: ...D Index D 2 Festo P BE SFC LAC CO EN en 0708NH Contents D Index D 1...