5. Commissioning
5−3
Festo P.BE−SFC−DC−IO−EN en 0801a
5.1
Preparing for commissioning
5.1.1
Check the connection to the mains power supply
Please note
Note that the tolerance for the supply voltage must be
observed. The tolerance must be observed directly at the
operating voltage connection of the SFC−DC.
The correct values can be found in chapter 3.2 and in the
technical specifications in the appendix.
5.1.2
Check the drive
Please note
During operation, the SLTE must not hit any stop without
shock absorption (exception: reference run).
Recommendation: Use shock absorbers or other suitable
buffer elements on all stops where no reference run is
being carried out.
·
Before commissioning the positioning drive, make sure
that:
the work space is of sufficient size for operation with a
work load
the work load does not collide with the motor or the
gear of the axis when the axis moves into the end
position
that the positioning drive is within the permitted posi
tioning range when it is switched on.
·
Please observe the notes in the operating instructions for
the positioning drive.
Summary of Contents for SFC-DC series
Page 4: ...Contents and general instructions II Festo P BE SFC DC IO EN en 0801a...
Page 18: ...Contents and general instructions XVI Festo P BE SFC DC IO EN en 0801a...
Page 19: ...System summary 1 1 Festo P BE SFC DC IO EN en 0801a Chapter 1...
Page 39: ...Fitting 2 1 Festo P BE SFC DC IO EN en 0801a Chapter 2...
Page 45: ...Installation 3 1 Festo P BE SFC DC IO EN en 0801a Chapter 3...
Page 62: ...3 Installation 3 18 Festo P BE SFC DC IO EN en 0801a...
Page 63: ...Control panel only type SFC DC H2 4 1 Festo P BE SFC DC IO EN en 0801a Chapter 4...
Page 84: ...4 Control panel only type SFC DC H2 4 22 Festo P BE SFC DC IO EN en 0801a...
Page 85: ...Commissioning 5 1 Festo P BE SFC DC IO EN en 0801a Chapter 5...
Page 129: ...Diagnosis and error treatment 6 1 Festo P BE SFC DC IO EN en 0801a Chapter 6...
Page 137: ...Technical appendix A 1 Festo P BE SFC DC IO EN en 0801a Appendix A...
Page 142: ...A Technical appendix A 6 Festo P BE SFC DC IO EN en 0801a...
Page 143: ...Supplementary information B 1 Festo P BE SFC DC IO EN en 0801a Appendix B...
Page 192: ...B Supplementary information B 50 Festo P BE SFC DC IO EN en 0801a...
Page 193: ...Index C 1 Festo P BE SFC DC IO EN en 0801a Appendix C...
Page 194: ...C Index C 2 Festo P BE SFC DC IO EN en 0801a Contents C Index C 1...
Page 202: ...C Index C 10 Festo P BE SFC DC IO EN en 0801a...