![Festo SFAB-PNLK Series Operating Instruction Download Page 16](http://html1.mh-extra.com/html/festo/sfab-pnlk-series/sfab-pnlk-series_operating-instruction_2282556016.webp)
16
Festo — SFAB-...-PNLK — 2022-08
Installation
5.3
Mounting the sensor on the plate
Fig. 8: Plate mounting
•
Fasten the sensor with washers and 2 screws M4.
–
Max. tightening torque: 1 Nm
5.4
Rotating the display
The display can be rotated in 90° steps. The turning range is limited to approx. 270° by a stop.
Fig. 9: Rotate the display
6
Installation
6.1
Installation, pneumatic
The flow rate is supplied at connection 1 and withdrawn at connection 2. The direction of flow is
indicated on the sensor by an arrow.
If the hoses are installed incorrectly, the negative measured values will flash on the display.