Translation of the original instructions
© 2020 all rights reserved to Festo
SE
& Co. KG
1
About this Document
This document describes the use of the above-mentioned product. For detailed
specifications on the product, a complete description, the software for the device
(IODD) and the declaration of conformity
è
1.1
Applicable documents
All available documents for the product
è
2
Safety
2.1
General Safety Instructions
–
Only use the product in original status without unauthorised modifications.
–
Only use the product if it is in perfect technical condition.
–
Take into consideration the ambient conditions at the location of use.
–
Observe limit values
è
Return to Festo
–
Consult your regional Festo contact.
2.2
Intended Use
–
The position transmitter SDAS-MHS is intended for monitoring the piston
stroke.
–
Only use the position transmitter for suitable drives from Festo
è
–
Avoid positioning magnetic objects in close proximity to the position trans-
mitter.
2.3
Training of qualified personnel
Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.
2.4
UL/CSA Certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
Approval Information UL/CSA
Product category code
NRKH/NRKH7
File number
E232949
Considered standards
UL 60947-1, UL 60947-5-2
CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-5-2
UL mark
UL control number
2MD1
Tab. 1 Approval Information UL/CSA
–
Technical data and environmental conditions may be subject to change in
order to comply with Underwriters Laboratories Inc. (UL) certification require-
ments for the USA and Canada.
Deviating values
è
11.2 Technical Data for UL/CSA Certification.
–
Only use power sources which guarantee reliable electrical isolation of the
operating voltage in accordance with IEC/EN 60204-1. Observe also the gen-
eral requirements for PELV power circuits in accordance with IEC/EN 60204-1.
–
Only for connection to a NEC/CEC Class 2 supply.
The device shall be supplied from an isolating transformer having a second-
ary listed fuse rated 1 A.
3
Service
Contact your regional Festo contact person if you have technical questions
è
4
Product overview
4.1
Design
1 Connecting cable
2 M8 plug, rotatable
3 Red LED: status indicator
4 Yellow LED: switching status dis-
play
5 Marking: centre of the sensing
range
6 Capacitive operating key
7 Retaining screw
Fig. 1 Design of SDAS-MHS
4.2
Function
The position transmitter detects the magnetic field of the piston magnet and con-
tinuously senses the piston movement in the sensing range. The position trans-
mitter can be operated in one of the following operating modes:
–
Proximity sensor with 2 programmable switching points (standard operation)
è
4.2.1 Proximity Sensor Operating Mode.
–
Position transmitter with IO-Link communication
è
4.2.2 Position Transmitter Operating Mode (IO-Link).
In the case of active IO-Link communication (IO-Link master required), the SDAS-
MHS switches automatically into the position transmitter operating mode.
4.2.1
Proximity Sensor Operating Mode
In the proximity sensor operating mode, 2 switching points can be programmed
within the sensing range.
–
Operation using capacitive operating key
–
Switching logic: normally open (NO)
–
Output signal 24 V DC (PNP or NPN)
–
Marking on the housing indicates the centre of the sensing range.
1 Electrical output 1
2 Electrical output 2
Fig. 2 Application example: Cylinder switch operating mode
8126470
SDAS-MHS
Position transmitter
8126470
2019-12b
[8126472]
Instructions | Operating
Festo
SE
& Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0