Fig. 285: Write name into SBS
5.6.3.10 Translate project and write to PLC
To finish the configuration and save changes of the project: 1. translate and 2. transfer / write to the PLC
Fig. 286: Translate project and write to PLC
5.6.4 Profinet- telegram description SBS
5.6.4.1 Module1: „Control“ (From PLC to SBS )
Name in PLC „CTRL (3 bytes)“
Byte-
Position
in
Module
Size
in
Bytes
Member
name
Data-
Type
Bit
number
Meaning
0
3
Reset
error
1 Bit
0
Reset Error clears 4bit Errorcode in Module: “Status”.
Rising edge (low ==> high) clears error code.
HW-
Trigger
Disable
1 Bit
1
This bit is set to disable triggering via the hardware trigger.
Valid for triggered and free-run mode.
Low (0): Hardware trigger or free run enabled.
High (1): Hardware trigger or free run disabled
If the HW-Pin "Trigger enable" is used, both (Digital input
“Hardware- Trigger” and “HW Trigger Disable Bit”) have to