![Festo SBO***-Q Series Manual Download Page 54](http://html1.mh-extra.com/html/festo/sbo-q-series/sbo-q-series_manual_2283437054.webp)
3. Installation
3-8
Festo P.BE-SBO-Q-EN en 1602e
M12 plug
1)
Pin
Signal
Description
Core colour
2)
1
8
6
5
7
2
4
3
1
I0
Rising edge
3)4)
: Trigger signal
White (WH)
2
24 V DC
+24 V DC (tolerance: ± 10 %)
Brown (BN)
3
Reserved
Do not connect
Green (GN)
4
O1
Logic 1:
Last evaluation indicated Good part
4)
Yellow (YE)
5
I1
Rising edge
3) 4)
:
Apply Inputs signal
Acknowledge Error signal in case of
error
Grey (GY)
6
O0
– Logic 1:
Device ready for operation (Ready)
4)
– Logic 0:
Device not yet ready for operation
(e.g. evaluation running, system
fault)
4)
Pink (PK)
7
0 V
0 V
Blue (BU)
8
O2
Logic 1: Last evaluation indicated
Reject part
4)
Red (RD)
Metal covering
5)
Screening (shield)
1)
Tighten union nut by hand
2)
Core colours of the original cable SIM-M12-8GD-...-PU
3)
The signal levels/edges can be configured via system parameters; the specified description
corresponds to the standard configuration.
4)
The function can be configured via system parameters; the specified description corresponds to
the standard configuration.
5)
Connect cable screening with low impedance to earth potential (
è
Tab. 3/3:
Operating voltage connection and I/Os at the 8-pin M12 plug “24 V DC”
The function and functional behaviour of the I/Os can be con
figured in CheckKon via system parameters. The functional
behaviour of the I/Os in the different evaluation modes must
be differentiated (
è
chapter 4.9 ff.).
Summary of Contents for SBO***-Q Series
Page 2: ......
Page 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Page 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Page 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Page 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Page 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Page 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Page 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Page 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Page 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...