Festo — CPX-AP-A-PN-M12 — 2022-07
Diagnostics and fault clearance
17
ID hex (dec)
Message
Description
0B | 00 | 0140
(184549696)
Systemstart
Diag-
nostic
status
Information
0B | 04 | 00B7
(184811703)
Firmware invalid
Firmware invalid
Remedy
–
Repeat transfer of firmware package.
Diag-
nostic
status
Error
0B | 07 | 00CC
(185008332)
Initialization failed
Initialization of device failed
Remedy
–
Check other diagnosis notifications.
–
Reset device to factory defaults.
Diag-
nostic
status
Error
0B | 08 | 018F
(185074063)
Unsupported Version
of full diagnostic
image
The version of the full diagnostic image is not supported.
Remedy
–
Check firmware versions of master and
devices and update to compatible versions.
Diag-
nostic
status
Error
0B | 08 | 0190
(185074064)
Unsupported Version
of diagnosis
The version of the diagnosis is not supported.
Remedy
–
Check firmware versions of master and
devices and update to compatible versions.
Diag-
nostic
status
Error
0B | 09 | 0128
(185139496)
Invalid APDD
The AP device description is invalid or missing.
Remedy
–
Reboot device.
–
Check communication cable.
–
Check firmware version.
–
On repeating failure contact Festo support.
Diag-
nostic
status
Error
0B | 09 | 0129
(185139497)
Invalid startup APDD
The startup AP device description is invalid or missing.