background image

Translation of the original instructions

© 2020 all rights reserved to Festo SE & Co. KG

1

About this document

1.1

Applicable documents

All available documents for the product 

è

 www.festo.com/sp.

Document

Product

Contents

Instruction manual

Manifold rail OABM-P

Assembly

Tab. 1 Applicable documents

2

Safety

2.1

Safety instructions

The product may only be used in its original status without unauthorised
modifications.

Only use the product if it is in perfect technical condition.

Use the product only inside buildings.

Take into consideration the ambient conditions at the location of use.

The product is intended for use in industrial environments. This product can
generate high frequency malfunctions, which may make it necessary to imple-
ment interference suppression measures in residential areas.

Observe the specifications on the product labelling.

Comply with all applicable national and international regulations.

Observe the local regulations for environmentally friendly disposal.

2.2

Intended use

The intended use of the product is to generate a vacuum.

2.3

UL certification

In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.

UL approval information

Product category code

QUYX (USA)
QUYX7 (Canada)

File number

E322346

Standards taken into account

UL 61010-1
C22.2 No. 61010-1

UL symbol

Tab. 2 Approval information
The unit shall be supplied by a power source which fulfils the requirements on a
limited-energy circuit in accordance to IEC/EN/UL/CSA 61010-1 or on a Limited
Power Source (LPS) in accordance to IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/CSA
62368-1 or a Class 2 circuit in accordance to NEC or CEC.

3

Further information

Accessories 

è

 www.festo.com/catalogue.

Spare parts 

è

 www.festo.com/spareparts.

4

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Product overview

5.1

Product design

1 Solenoid valve for ejector pulse

(eject)

2 Solenoid valve for vacuum

3 Mechanical manual override

4 Supply port (1)

5 Exhaust port/silencer (3)

6 Vacuum port (2)

7 Housing with mounting hole

8 Slide for changing the filter ele-

ment

9 Filter housing with display window

10 Flow control screw for adjusting

the ejector pulse

11 EDIT button

12 LED for switching output – Out

13 LED for switching input – vacuum

ON/OFF

14 LED for switching input – ejector

pulse (eject)

15 Electrical connection

16 Size OVEM-...-20/-30-C

Fig. 1 Operating elements and connections

LED for switching output Out and EDIT pushbutton not installed for types without
vacuum sensor

Filter housing with inspection window only with OVEM-...-B

5.1.1

Product variants

Product variant

Code

Meaning

Vacuum generator

OVEM

Vacuum generator with solenoid valve and manual over-
ride

-05

0.45 mm

-07

0.7 mm

-10

0.95 mm

-14

1.4 mm

-20

2.0 mm

Nominal width of Laval
nozzle

-30

3.0 mm

-H

high negative pressure

Vacuum type

-L

high suction volume

-B

20 mm wide, ISO standard

-BN

20 mm wide, NPT

Housing size/width

-C

36 mm wide, ISO standard

all ports with QS push-in fittings (-B-QS/-C-QS)

-QS

all ports with QS push-in fittings inch (-BN-QS)

Supply/vacuum port with QS push-in fittings, exhaust
port with open silencer (-B-QO/-C-QO)

-QO

Supply/vacuum port with QS push-in fittings inch,
exhaust port with open silencer (-BN-QO)

all ports with G female thread (-B-GN/-C-GN)

-GN

all ports with NPT female thread (-BN-GN)

Supply/vacuum port with G female thread, exhaust port
with open silencer (-B-GO/-C-GO)

-GO

Supply/vacuum port with NPT female thread, exhaust
port with open silencer (-BN-GO)

Pneumatic ports

-PL

prepared for common supply manifold, vacuum and
exhaust port with QS push-in fittings (-B-PL/-C-PL)

8140354

OVEM-...-1P/1N

Vacuum generator

8140354
2020-07e
[8140356]

Operating instructions

Festo SE & Co. KG 
73734 Esslingen 
Ruiter Straße 82 
Germany
+49 711 347-0 

www.festo.com 

Summary of Contents for OVEM 1P Series

Page 1: ...arts è www festo com spareparts 4 Service Contact your regional Festo contact person if you have technical questions è www festo com 5 Product overview 5 1 Product design 1 Solenoid valve for ejector pulse eject 2 Solenoid valve for vacuum 3 Mechanical manual override 4 Supply port 1 5 Exhaust port silencer 3 6 Vacuum port 2 7 Housing with mounting hole 8 Slide for changing the filter ele ment 9 F...

Page 2: ...ive switching pressure sensor output A Switching input negative switching without vacuum sensor Switching input positive switching Tab 6 Switching output and switching input variants Determination of switching point The switching point SP is determined from the teach point TP and the function reserve 35 SP TP 0 35 TP The hysteresis has a fixed value 5 2 2 Valve control Control of the ejector pulse...

Page 3: ...of the screws for mounting with mounting bracket Mounting on common supply manifold OVEM B BN Mounting is possible on a common supply manifold with a max imum of 8 places OVEM C Mounting is possible on a common supply manifold with a maximum of 4 places Assembly instructions for common supply manifold OABM P è www festo com sp 7 Installation 7 1 Pneumatic installation OVEM Symbol with vacuum senso...

Page 4: ...ed è 6 Assembly Checking operating conditions Check operating conditions and critical limits è 14 Technical data Commissioning the vacuum generator OVEM OE OPE 1 Apply operating pressure to supply port 1 Ä Negative pressure is generated at the vacuum port 2 2 Switch on the operating voltage Ä The current pressure is displayed and the vacuum generator is ready for operation Commissioning the vacuum...

Page 5: ...tor pulse Tubing dimensioned incorrectly Replace tubing tubing dimen sions è 7 1 Pneumatic installation Workpiece is not released by the suction gripper Flow control screw closed Open flow control screw Short circuit or overload at the out put Eliminate short circuit over load Device faulty Replace device Switching output does not react in accordance with the settings Incorrect switching point tau...

Page 6: ...h 11 ms duration half sine Vibration resistance in accordance with EN 60068 2 10 60 Hz 0 35 mm 60 150 Hz 5g Protection class III Degree of protection IP 651 Relative humidity 5 85 Interference emission as per EN 61000 6 4 Immunity to interference as per EN 61000 6 2 Maximum permissible signal line length m 20 Materials Information on materials seals NBR HNBR Information on materials housing Die ca...

Reviews: