background image

11

Accessories

Name

OVEM−05

OVEM−07/10

OVEM−14

Connecting  cable  M12x1,  5−pin,  2.5m

NEBU−M12G5−K−2.5−LE5

Connecting  cable  M12x1,  5−pin,  5m

NEBU−M12G5−K−5−LE5

H−rail  mounting

OABM−H

Mounting  bracket

HRM−1

Silencer  extension

UOMS−¼

UOMS−¼

Common  supply  manifold

OABM−P−4

pp y

OABM−P−6

OABM−P−8

Blanking  plug

OASC−G1−P

Fig.20 Accessories

12

Technical  data

OVEM

−05

−07/−10

−14

Operating  pressure

[bar]

2

Ū

8

Operating  pressure

[bar]

QS/GN/PL−

Ū

−1P/1N:  2

Ū

6

Operating  medium

Filtered,  unlubricated  compressed  air,
grade  of  filtration  40

ì

m

Ambient  temperature

[°C]

0

Ū

50

Temperature  of  medium

[°C]

0

Ū

50

Nominal  operating  voltage

[V  DC]

24  ±15%

Idle  current

1)

[mA]

<

80

Coil  characteristics  24  V  DC

[W]

Low−current  phase:  0.3

[ ]

High−current  phase:  2.55

Time  until  current  reduction

[ms]

<

80

Ready−state  delay

[ms]

500

Switching  output

 Max.  output  current

[mA]

100

 Voltage  drop

[V]

1.5

 Capacitive  load  max.  DC

[nF]

100

 Reaction  time

[ms]

<

12

22

35

Protective  functions

 Inductive  protective  circuit

Adapted  to  MZ,  MY,  ME  coils

 Protection  against  short  circuit

Yes

 Overload  protection

Yes

Reverse  polarity  protection

For  all  electrical  connections

Protection  class

IP65

Electrical  protection  class

3

Interference  immunity

See  declaration  of  conformity  (www.festo.com)

Interference  emission

See  declaration  of  conformity  (www.festo.com)

Vibration  resistance

As  per  DIN/IEC  68/EN  60068  part  2−6:
0.35  mm  travel  at  10 

Ū

  60  Hz, 

5  g  acceleration  at  60 

Ū

  150  Hz

Shock  resistance

As  per  DIN/IEC  68/EN  60068  part  2−27:
30  g  acceleration  at  11ms  duration  (half−sine)

Max.  permitted  signal  line  length

[m]

30

Overload  pressure  at  vacuum  port

[bar]

1P/1N: 

5

Overload  pressure  at  vacuum  port

[bar]

Without  vacuum  sensor: 

10

Pressure  measuring  range

3)

[bar]

1

Ū

0

Repetition  accuracy  of  switching
value

2)3)

[%  FS]

Max.  ±0.3

Temperature  co−efficient

2)3)

[%  FS/K] ±0.05

Setting  range  for  threshold  values

3)

[bar]

1

Ū

0

Hysteresis,  fixed

3)

[mbar]

20

1)

Both  solenoid  valves  are  actuated

2)

%  FS  =  %  of  the  final  value  in  the  measuring  range  (full−scale)

3)

Technical  feature  only  relevant  for  models  with  vacuum  sensor

Fig.21 Technical  data

Reviews: