Festo — MSE6-C2M — 2022-08b
Commissioning
49
System supply
The energy efficiency module is supplied with power via an AIDA push-pull connector or an M12
connector.
Plugs
Pin
Function
Description
AIDA push-pull
1
24 V DC U
El/Sen
Operating voltage supply for electronics and
sensors
2
0 V
U
El/Sen
Earth for electronics and sensors
3
24 V DC U
Out/A
Load voltage supply for actuators, outputs
and valves
4
0 V
U
Out/A
Earth for actuators, outputs and valves
5
FE
–
Functional earth
Tab. 28: Pin allocation system supply AIDA push-pull connector, MSE6-C2M-...-AMI
Plug, 5-pin
Pin
Function
Description
M12, L-coded
1
24 V DC U
El/Sen
Operating voltage supply for electronics and
sensors
2
0 V
U
Out/A
Earth for actuators, outputs and valves
3
0 V
U
El/Sen
Earth for electronics and sensors
4
24 V DC U
Out/A
Load voltage supply for actuators, outputs
and valves
FE
FE
–
Functional earth
Tab. 29: Pin allocation system supply M12 connector, L-coded, MSE6-C2M-...-M12L5
Plug, 4-pin
Pin
Function
Description
M12, L-coded
4
1
3
2
1
24 V DC U
El/Sen
Operating voltage supply for electronics and
sensors
2
0 V
U
Out/A
Earth for actuators, outputs and valves
3
0 V
U
El/Sen
Earth for electronics and sensors
4
24 V DC U
Out/A
Load voltage supply for actuators, outputs
and valves
Tab. 30: Pin allocation system supply M12 connector, L-coded, MSE6-C2M-...-M12L4
8
Commissioning
8.1
Safety
The product is equipped with a pneumatically-piloted proportional-pressure regulator and a down-
stream shut-off valve.