Technical data
MS6-SV-E
Degree of protection
IP65 with multi-pin plug socket NECA
Protection against electric
shock (protection against direct
and indirect contact in accord-
ance with EN/IEC 60204-1)
by PELV fixed power supply
Switching position indicator
LED and potential-free contact
Operating voltage
Nominal operating voltage DC
[V]
24
Current consumption
[A]
£
0.12
1)
Voltage fluctuations
Permissible voltage fluctuations [%]
±
10
Switching time
Switching time off
[ms]
40
Switching time on
[ms]
130
Duty cycle
[%]
100
Semiconductor relay (signal contact)
Voltage
[V]
£
60
continuous current
[A]
£
0.12
Resistance in switched-on
status
[Ω]
£
25
Leakage current in switched-off
status
[µA]
£
1
Protection class
III
1) A high starting current will apply briefly when switching on.
Tab. 11: Technical Data, Electrical
12.4
Safety characteristics
Type
MS6-SV-E
Conforms to standard
EN ISO 13849-1
EN ISO 13849-2
EN 61508-1:2010-05
Safety function
safe venting and protection against unexpected start-up
(pressurisation)
Performance Level (PL)
Category 4, PL e
Safety Integrity Level (SIL)
SIL 3