6. Install new filter cartridge:

Hold filter cartridge at the bottom and push onto the support.

Position filter plate, screw in and hand-tighten. Tightening torque:
0.07 Nm ±20% 

7. Mount filter bowl 

5

:

Align lock release of filter bowl on the cutout on the housing and insert it.

Turn filter bowl clockwise until the lock audibly locks at the end stop.

9.3

Clean product

Clean the outside of the product with a soft cloth as required. Cleaning agents
include all non-abrasive media.

10

Fault clearance

Error description

Cause

Remedy

Constriction in the supply line

Check supply line.

Low flow rate (operating pres-
sure breaks down with air con-
sumption)

Filter cartridge dirty

Replace filter cartridge

è

 9 Maintenance.

Pressure increases above the
set working pressure.

Valve disc defective at sealing
seat

Replace product.

Audible, continuous blowing
noise at rotary knob

Valve seat damaged

Replace product.

Blowing noise can be heard at
the drain screw.

Drain screw leaking

Replace product.

Tab. 3 Fault clearance

11

Disassembly

1. Exhaust the complete system and product.
2. Release interlock at the fittings by pressing it and pull out hose assembly.
3. Release fittings at the connecting flanges and unscrew.

12

Disposal

Dispose of the packaging, used filters and product at the end of the produc-
tion service life according to the valid provisions for environmentally sound
recycling.

13

Technical data

13.1

Technical data, mechanical

Size

MS2-LFR

Mounting position

[°]

ve/– 5

Grade of filtration

[µ]

5

Condensate drain function

manual turning

Temperature ranges

Temperature of medium

[°C]

–5 … 50

Ambient temperature

[°C]

–5 … 50

Storage temperature

[°C]

–5 … 50

Tab. 4 

13.2

Technical data, pneumatic

Size

MS2-LFR

Compressed air quality

Operating medium

Compressed air to ISO 8573-1:2010 [7:4:4]

Air quality class at the output

Compressed air to ISO 8573-1:2010 [6:4:4]

Pneumatics

Pneumatic connection
M5

[bar]

1 … 10

Pneumatic connection
QS6

[bar]

1 … 8

Pressure regulation range

[bar]

0.5 … 7

Standard nominal flow rate

Pneumatic connection
M5

[l/min]

140

Pneumatic connection
QS6

[l/min]

310

Tab. 5 