A. Technical appendix
A−11
Festo P.BE−MPAL−EN en 1008NH
Electric components, valve terminal MPA−L with CPX terminal
Electronic module VMPA...−FB−...
Operating voltage supply for electronic compo
nents (V
EL/SEN
):
Nominal voltage
Max. intrinsic current consumption at 24 V
(internal electronics, all outputs logic 0)
DC 24 V ±10%
13mA
Load voltage supply for valves (V
VAL
)
Nominal voltage
Max. intrinsic current consumption at 24 V
(internal electronics, without valves)
Diagnostic message undervoltage V
VAL
, load
voltage outside function range
DC 24 V ±10%
35mA
Ţ
17.7 V
Maximum current consumption per solenoid
coil at load voltage V
VAL
at 24 V
Nominal pick−up current/duration
Nominal current with current reduction
50mA/20ms
10mA
Tab.A/8: Technical specifications on electric components, valve terminal MPA−L with
CPX terminal
Summary of Contents for MPA-L Series
Page 2: ......
Page 8: ...Contents and general safety instructions VI Festo P BE MPAL EN en 1008NH ...
Page 15: ...Overview of components 1 1 Festo P BE MPAL EN en 1008NH Chapter 1 ...
Page 40: ...1 Overview of components 1 26 Festo P BE MPAL EN en 1008NH ...
Page 41: ...Mounting 2 1 Festo P BE MPAL EN en 1008NH Chapter 2 ...
Page 55: ...Installation 3 1 Festo P BE MPAL EN en 1008NH Chapter 3 ...
Page 85: ...Commissioning 4 1 Festo P BE MPAL EN en 1008NH Chapter 4 ...
Page 100: ...4 Commissioning 4 16 Festo P BE MPAL EN en 1008NH ...
Page 101: ...Conversion and maintenance 5 1 Festo P BE MPAL EN en 1008NH Chapter 5 ...
Page 128: ...5 Conversion and maintenance 5 28 Festo P BE MPAL EN en 1008NH ...
Page 129: ...Technical appendix A 1 Festo P BE MPAL EN en 1008NH Appendix A ...
Page 141: ...Supplementary overview of components B 1 Festo P BE MPAL EN en 1008NH Appendix B ...
Page 150: ...B Supplementary overview of components B 10 Festo P BE MPAL EN en 1008NH ...
Page 151: ...Index C 1 Festo P BE MPAL EN en 1008NH Appendix C ...
Page 152: ...C Index C 2 Festo P BE MPAL EN en 1008NH Contents C Index C 1 ...