6
Operation
56
Festo – EXCM-10/-30-...-E-EN – 1612b – English
Confirmation (acknowledge)
Byte
Description
Remedy
0x00
Everything OK.
–
0x01
Service is not supported.
Check the service ID of the request.
0x03
User data length of the request is invalid.
Check the structure of the request.
0xA0
Range of values of another CVE object violated.
Correct range of values.
0xA2
Invalid object index.
Correct the object index.
0xA4
The CVE object cannot be read.
–
0xA5
The CVE object cannot be written.
–
0xA6
The CVE object cannot be written while the drive is
in an “Operation enabled” status.
Quit the “Operation enabled” status.
0xA7
The CVE object must not be written without master
control.
Setting and releasing the control
interface in the FCT.
0xA9
The CVE object cannot be written, as the value is
lower than the minimum value.
Correct the value.
0xAA
The CVE object cannot be written, as the value is
greater than the maximum value.
Correct the value.
0xAB
The CVE object cannot be written, as the value is
not within the valid value set.
Correct the value.
0xAC
The CVE object cannot be written, as the specified
data type is incorrect.
Correct the data type.
0xAD
The CVE object cannot be written, as it is password
protected.
Remove password protection via FCT.
0xE0
Control interface is blocked by FCT.
Enabling the control interface in the
FCT.
Tab. 6.17 Confirmation (acknowledge)