8
Festo — CPX-AP-A-EC-M12 — 2022-07
Product overview
4.2.3
Control elements
NOTICE
Damage to internal electronics.
Damage to at-risk components due to electrostatic discharge.
• Ensure your body is electrostatically discharged before activating the rotary switch.
Rotary switches
Function
The 3 rotary switches are used to set the EtherCAT "Explicit Device
ID" of the interface in hexadecimal code.
Possible settings:
–
0 = stored EtherCAT address, no "Explicit Device ID" assigned
–
1 … 4094 (1
h
… fff
h
) = permissible address range
–
4095 (0xFFF) = reset to factory setting
If set to 0, the address of the interface is automatically assigned
by the EtherCAT master (autoincrement).
Factory setting: 0
Tab. 5: Rotary switches
Changes to the rotary switches only take effect following a restart of the interface.
4.2.4
Connecting elements
Connection for system communication [XF20]
Socket M8, 4-pin, D-coded
Signal
1
RX–
Received data –
2
TX+
Transmitted data +
3
RX+
Received data +
4
TX–
Transmitted data –
Tab. 6: Connection for system communication
Connection for EtherCAT network [IN XF1]
Socket M12, 4-pin, D-coded
Signal
1
TD+
Transmitted data +
2
RD+
Received data +
3
TD–
Transmitted data –
4
RD–
Received data –
Thread
Shield Functional earth FE
Tab. 7: Connection for EtherCAT network [IN XF1]