14.2.4
System parameters
The system parameters contain all command data (e.g. start and stop, power stage control, ...) dis-
played as buttons in the application software interface to control the drive system.
Index.
Subindex
Name
Description
Data type
(length)
User access
1)
U = User
M = Maintenance
personnel
S = Specialist
U
W
S
System commands for con-
trolling the drive unit
Value 0xC8 (200) execute Mov
In
–
Control command for execut-
ing the motion "Mov
In
" to
the "Lim
In
("Ref")” end posi-
tion
è
Value 0xC9 (201) execute Mov
Out
–
Control command for execut-
ing the motion "Mov
Out
" to
the "Lim
Out
" end position
è
Value 0xCA (202) Stop motion
–
Control command for stop-
ping travel.
è
0x0002.0
(2.0)
SystemCom-
mand
Value 0xCB (203) Disable power
stage
–
Control command for switch-
ing off the power stage.
è
UIntegerT
(1 byte)
–
W
W
0x0002.0
(2.0)
SystemCom-
mand
Value 0xCC (204): Enable power
stage
UIntegerT
(1 byte)
–
W
W
IO-Link