F
Diagnostics and fault clearance
372
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
F.1.1
LED indicator for the operating status of the device (EMCA-…-CO/-DIO/-EC/-EP/-PN)
1
2
1
LED OK
2
LED ERROR
Fig. F.1
LED indicator for the operating status of the device (example EMCA-EC-67-S-1TE-DIO)
F.1.2
Behaviour during the switch-on phase
LED
LED status
Event/status
OK
Flashes green
–
Start-up phase, bootloader active
ERROR
Flashes red
Tab. F.2
Behaviour in the switch-on phase
F.1.3
Behaviour in the operating phase
LED
LED status
Event/status
OK
Off
–
Hardware is not ready for operation; an error is present.
Flashes green
–
Hardware is ready for operation; but the signal “Control enable” is
not present.
Green
–
Normal operating status; hardware is ready for operation; signal
“Control enable” is present
ERROR
Off
–
No error, no warning
Flashes red
–
A warning is indicated.
Red
–
An error is reported.
Tab. F.3
Behaviour in the operating phase
F.1.4
Identification sequence active
LED
LED status
Event/status
OK
Flashing at the
same time
Feedback to the optical identification active (can be activated
through FCT and the web server)
ERROR
Tab. F.4
Identification sequence active
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......