10
Control via FHPP
158
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
10.4.4
Diagram: Homing to reference/limit switch
The diagram shows as an example homing to the reference or limit switch in a positive direction (refer
ence point REF) without index with subsequent travel to the axis zero point (AZ).
Start homing
(CPOS.HOM, B2)
Search speed
(PNU 1012.1)
Acceleration/deceleration
(PNU 1013.1)
Axis is moving
(SPOS.MOV, B4)
Motion complete
(SPOS.MC, B2)
t
t
t
t
t
Creep speed
(PNU 1012.3)
Travel speed
(PNU 1012.2)
Reference point (REF)
Axis zero point (AZ)
Drive referenced
(SPOS.REF, B7)
t
Offset axis zero point
(PNU 1010.1)
Acknowledge start
(SPOS.ACK, B1)
t
Reference/limit switches
t
t
Position
Fig. 10.4 Diagram: Diagram: Homing to reference/limit switch in a positive direction
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......