![Festo CPX-FB38 Electronic Manual Download Page 87](http://html1.mh-extra.com/html/festo/cpx-fb38/cpx-fb38_electronic-manual_2284150087.webp)
2. Commissioning
2−51
Festo P.BE−CPX−FB38−EN en 0804NH
2.7
Application example for the parameterisation
1
Input for
1stsensor
(with default
parameterisation)
2
Parameterised
input for
2ndsensor
(see text)
Î
Î
2
1
1. Sensor
2. Sensor
Fig.2/10: Application example for parameterisation of the input debounce time and
signal extension time on the 2nd sensor
In the above application, packets are transported on a
fast−moving conveyor belt.
The input for the 2nd sensor is parameterised as follows for
improvement of the signal recording and processing:
Reduction of the input debounce time from 3ms (factory
setting) to 0.1ms: Recording shorter signals is possible.
This parameter is set for the complete module.
Signal extension time set to 50ms: Reliable recording of
the signals by the controller.
The value of this parameter is set for the complete
module but must be activated or deactivated separately
for each input channel.
Summary of Contents for CPX-FB38
Page 2: ......
Page 8: ...Contents and general instructions VI Festo P BE CPX FB38 EN en 0804NH...
Page 17: ...Installation 1 1 Festo P BE CPX FB38 EN en 0804NH Chapter 1...
Page 37: ...Commissioning 2 1 Festo P BE CPX FB38 EN en 0804NH Chapter 2...
Page 91: ...Diagnosis 3 1 Festo P BE CPX FB38 EN en 0804NH Chapter 3...
Page 111: ...Technical appendix A 1 Festo P BE CPX FB38 EN en 0804NH Appendix A...
Page 115: ...Index B 1 Festo P BE CPX FB38 EN en 0804NH Appendix B...
Page 116: ...B Index B 2 Festo P BE CPX FB38 EN en 0804NH Contents B Index B 1...