Connection status [XF1], [XF2]
LED
(green)
Meaning
Remedy
Flashes
Module locating in progress when both
LEDs are flashing in synchronisation,
e.g. for troubleshooting or configuration.
–
Off
No connection at the respective port or
line not connected.
Check network connection.
Tab. 15 Connection Status [XF1], [XF2]
12
Disposal
ENVIRONMENT!
Send the packaging and product for environmentally sound recycling in accord-
ance with the current regulations
è
13
Technical Data
13.1
General Technical Data
General technical data
General technical data
Automation system CPX-E
Description of automation system CPX-E
è
Dimensions
(length x× width × height)
1)
[mm]
124.3 × 75.9 × 82.5
Product weight
2)
[g]
288
Mounting position
Vertical/horizontal
Ambient temperature with
vertical mounting position
[°C]
–5 … +60
3)
Ambient temperature with
horizontal mounting position
[°C]
–5 … +50
3)
Storage temperature
[°C]
–20 … +70
Humidity
(non-condensing)
[%]
0 … 95
Degree of protection in accordance with
EN 60529
IP20
The degree of protection is not UL-tested.
Protection against electric shock
(Protection against direct and indirect
contact in accordance with IEC 60204-1)
through the use of PELV circuits
(protected extra-low voltage)
Electromagnetic compatibility
To EN 61000-6-2/-4 and NE 21
Module code/sub-module code
CPX-E-CEC-C1-PN
222/100
CPX-E-CEC-M1-PN
222/101
Module identification
CPX-E-CEC-C1-PN
E-CEC-C1-PN
CPX-E-CEC-M1-PN
E-CEC-M1-PN
1) Including covering, not including linking element
2) Including linking element
3) for non-conforming technical data see UL operating conditions table UL
Tab. 16 General Technical Data
Power supply
Operating power supply
U
EL/SEN
[V DC]
24
_
25%
Intrinsic current consumption
at nominal operating voltage
24 V from U
EL/SEN
[mA]
130
Reverse polarity protection
24 V U
EL/SEN
against 0 V
U
EL/SEN
Yes
Mains buffering time
[ms]
20
Tab. 17 Power Supply
Network-specific data
Protocol
PROFINET
1)
, EtherCAT
Specification
Standards and norms with reference to PROFINET:
IEC 61158
IEC 61784
IEC 61918
Transmission rate
[Mbps]
100
Crossover detection
Auto-MDI/MDI-X
Maximum cable length per
segment
[m]
100
Cable specification
Cable type
Ethernet twisted pair cable, shielded
Transmission class
Category Cat 5 or higher
Cable diameter
[mm]
6 … 8
Wire cross section
[mm
2
]
0.14 … …0.75; 22 AWG
2)
1) based on the Ethernet protocol IEEE 802.3
2) required for maximum connection length between network participants
Tab. 18 Network-specific Data
13.2
Technical Data UL/CSA Certification
Ambient conditions UL/CSA
Pollution degree
3
Installation site
for indoor use only
Max. installation height
[m]
2000
Tab. 19 Ambient Conditions UL/CSA
Ambient temperature
Mounting position
Vertical
Horizontal
Operating power supply U
EL/SEN
via XD
Ambient temperature, max. current rating
of terminal strip
£
4 A
[°C]
–5 … +60
–5 … +50
Ambient temperature, max. current rating
of terminal strip
>
4 … 8 A
[°C]
–5 … +50
–5 … +40
Operating voltage U
EL/SEN
with feed via both connections [XD]
1)
Ambient temperature, max. current rating
of terminal strip
>
4 … 8 A
[°C]
–5 … +60
–5 … +50
1) see chapter 'Product design' or 'Connection elements'
Tab. 20 Ambient temperature ranges