background image

Analogue output modules
CPX-E-…AO-U-I

Festo AG & Co. KG

Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com

Instructions for use
Original instructions

8071083
2017-07
[8071085]

Analogue output modules CPX-E-…AO-U-I

English

. . . . . . . . . . . . . . . . . . . . . . . . . .

Reproduction, distribution or sale of this document or communication of its con­
tents to others without express authorization is prohibited. Offenders will be liable
for damages. All rights reserved in the event that a patent, utility model or design
patent is registered.

1

About this document

This document describes the use of the above-mentioned products. Certain
aspects of use are described in other documents and must be observed

è

 1.1 Further applicable documents.

1.1 Further applicable documents

Document

Table of contents

Description  of system CPX-E (CPX-E-SYS)

Detailed description of system CPX-E

Instructions for using system CPX-E (CPX-E-SYS)

Instructions and important notes on mounting,
electrical installation and maintenance tasks
for a system CPX-E

Description of analogue output modules
CPX-E-…AO-U-I (CPX-E-…AO-U-I)

Detailed description of product function and
parameterisation possibilities

Documentation for the components in a system
CPX-E and the connected peripherals

Information on using the components

Documentation for the higher-order controller
and the additional participants in the network

Information on commissioning and
parameterisation of the components

Fig. 1

For all available product documentation 

è

 www.festo.com/pk

1.2 Product version

This document refers to the following product versions:

Product

Version

CPX-E-4AO-U-I

Analogue output module CPX-E-4AO as of Revision 1

Fig. 2

The product version can be identified from the product label or with the help of
appropriate software from Festo.

Suitable software for determining the product version is available on the

support portal of Festo 

è

 www.festo.com/sp. Information on using the

software can be found in the integrated Help function.

There may be an updated version of this document for these or later

product versions.

 Check whether a corresponding version of this document is available on

the Festo Support Portal 

è

 www.festo.com/sp.

1.3 Product labelling

The product label is located on the left-hand side of the module.
Scanning the printed Data Matrix Code with an appropriate device calls up the
Festo Support Portal, with information appropriate for the product. Alternatively,
the product key (11-digit alphanumeric code or product label) can be entered in
the search field of the Support Portal.

You can find detailed information on the product labelling in the descrip­

tion of the module 

è

 1.1 Further applicable documents.

1.4 Specified standards

Version

EN 60529:2013-10

EN 61000-6-4:2007-01

EN 61000-6-2:2005-08

IEC 60204-1:2014-10

Fig. 3

2

Safety

2.1 General safety informations

 Take into consideration the legal regulations for the respective destination.
 Use the product only within the defined values 

è

 13 Technical data.

 Observe labelling on the product.
 Observe further applicable documents 

è

 1.1 Further applicable documents.

 Store the product in a cool, dry, UV-protected and corrosion-protected environ­

ment. Ensure that storage times are kept to a minimum.

 Before working on the product: Switch off the power supply and secure it

against being switched on again.

 Comply with the handling specifications for electrostatically sensitive devices.

2.2 Intended use

The products described in this document are exclusively for use in systems CPX-E.
The products must be used only as follows:
– In an industrial environment only: Outside of industrial environments – in com­

mercial and mixed-residential areas, for example – actions to suppress interfer­
ence may have to be taken.

– Use only in combination with modules and components that are permissible for

the respective product variant 

è

 www.festo.com/catalogue.

– Only use the product if it is in perfect technical condition.
– Only use the product in original status without unauthorised modifications. Only

the conversions or modifications described in this and the other applicable doc­
uments are permitted.

2.3 Qualification of specialized personnel

Installation, commissioning, maintenance and disassembly should only be conduc­
ted by qualified personnel.
The qualified personnel must be familiar with installation and operation of elec­
trical control systems.

3

Further information

– Accessories 

è

 www.festo.com/catalogue

– Spare parts 

è

 www.festo.com/spareparts

4

Service

 Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Summary Product

5.1 Function

Analogue output modules CPX-E-…AO-U-I in a system CPX-E provide analogue
outputs for connecting actuators.

5.2 Product design

1

LED indicators

2

Terminal strips of outputs
[X0] … [X3]

3

Terminal strip functional earth [X4]

4

Terminal strip of load voltage
supply U

OUT

 [XD]

5

Terminal strip interlock

6

Linking

2

3

4

5

6

1

Fig. 4

5.3 Display components

1

Module error [

P

] (red)

2

Channel error output 0 … 3 (red)
– Output 0 [X0]
– Output 1 [X1]
– Output 2 [X2]
– Output 3 [X3]

3

Load voltage supply U

OUT

 [PL]

(green)

1

2

3

Fig. 5

Reviews: