3. Electrical installation
3−11
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
3.3
Ensuring protection class IP65
With a completely installed axis string (all plug connectors
inserted), the CMAX in the CPX terminal complies with protec
tion class IP65.
Note
To comply with protection class IP65:
·
Seal unused connections with the corresponding protec
tive caps.
If the axis interface is not used, then seal this using a FLANGE
RECEPTACLE, S712 protective cap. You will then comply with
protection class IP65.
For the VPWP, a protective cap of type ISK−M8 for the output
(DO, brake) is included in the scope of delivery.