2. Fitting and pneumatic installation
2−26
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
1
Working line 2
(blue releasing ring):
}
Drive moves in a
positive direction
2
Working line 4
(black releasing ring):
}
Drive moves in
negative direction
3
VPWP proportional
directional control
valve
4
Filter regulator with
5m filter, without
lubricator
1
2
+
3
4
Fig.2/10: Pneumatic circuit diagram
Drive with dis
l
t
d
Direction of movement
Block circuit diagram
placement encoder
Negative ()
Positive (+)
DGCI
Towards the dis
l
d
Away from the dis
l
d
2
4
DGP(L) with
MLO−POT−...−TLF
placement encoder
connection
y
placement encoder
connection
2
4
DNCI
4
2
DNC with
MLO−POT−...−LWG
Retracted piston
rod
Extended piston rod
4
2
DNCM
4
2
DSMI
Clockwise (view of
stop lever)
Anticlockwise (view
of stop lever)
4
2
Tab.2/10: Direction of movement and tubing
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...