1. Overview and connection technology I/O modules
1−19
Festo P.BE−CPX−AX−EN en 0503b
A
ssem
bly
1
Cut the cable to
length and remove
the coating. Push the
union nut and seal
onto the end of the
cable.
2
Insert the ends of the
core into the ap
propriate slots of the
splicing ring.
3
Place the seal and
the splicing ring
together and cut off
the projecting core
ends flush with the
splicing ring.
4
Insert the pre−fitted
splicing seal element
into the contact sup
port in the sub−base.
Screw in the union
nut as far as possible.
1
2
4
3
1
2
4
3
Fig.1/6: Connecting the cables to sub−base CPX−AB
D
ismant
l
in
g
·
Loosen the screw connector and remove the cores by
pulling them out of the contacts.
The cores can be connected up to 10 times if the contact
ends are cut away each time (if the same core diameter is
used). Cut off the cable ends used and repeat steps 2 to 4.
Summary of Contents for CPX-2AA-U-I
Page 2: ......
Page 19: ...Overview and connection technology I O modules 1 1 Festo P BE CPX AX EN en 0503b Chapter 1...
Page 44: ...1 Overview and connection technology I O modules 1 26 Festo P BE CPX AX EN en 0503b...
Page 45: ...Analogue input module CPX 2AE U I 2 1 Festo P BE CPX AX EN en 0503b Chapter 2...
Page 83: ...Analogue input module CPX 4AE I 3 1 Festo P BE CPX AX EN en 0503b Chapter 3...
Page 122: ...3 Analogue input module CPX 4AE I 3 40 Festo P BE CPX AX EN en 0503b...
Page 123: ...Analogue input module CPX 4AE T 4 1 Festo P BE CPX AX EN en 0503b Chapter 4...
Page 157: ...Analogue output module CPX 2AA U I 5 1 Festo P BE CPX AX EN en 0503b Chapter 5...
Page 198: ...5 Analogue output module CPX 2AA U I 5 42 Festo P BE CPX AX EN en 0503b...
Page 199: ...Technical appendix A 1 Festo P BE CPX AX EN en 0503b Appendix A...
Page 221: ...Index B 1 Festo P BE CPX AX EN en 0503b Appendix B...
Page 222: ...B Index B 2 Festo P BE CPX AX EN en 0503b Contents B Index B 1...