![Festo CMMT-ST-SW Original Instructions Manual Download Page 512](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377512.webp)
Parameters and diagnostic messages
ID Px.
Parameters
Description
Specifies the number servo drive operating hours.
Access
read/−
Update
effective immediately
1423
Operating hour
counter
Unit
s
Tab. 450 Parameters
Example
The operating hours counter should be read.
Parameter settings (example)
Parameters
Value
Comment
Operating hour counter
P0.1423.0.0
...
Number servo drive operating hours
Tab. 451 Parameter settings (example)
Diagnostic messages
No specific diagnostic messages are allocated to the function.
9.6.3.1
CiA402
Operating hour counter objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
1423
0x2133.02
Operating hour counter
FLOAT32
Tab. 452 Objects
10
Web server
10.1
Function
A web server is integrated into the device. The web server provides access to a dynamic English-lan-
guage website for the device. If access is prevented via web server, the web server can be deactivated
with the parameter Px.11280051. The website of the web server enables, for example, the following:
–
Setting the IP configuration
–
Diagnostics of servo drive
–
Transfer of parameter files and firmware (upload and download)
Prerequisites for online connection with the web server
–
The power supply of the device is switched on.
–
The IP configuration of the device including subnet mask is set correctly.
Web server
512
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW