Name
Description
t2
Duration of stop detection
t3
Duration of travel to the axis zero-point
t4
Setpoint value time monitoring window stop detection
v1
Target velocity search
v2
Target velocity travel
x1
Reference mark stop
x2
Axis zero point
x3
Axis zero point offset
x4
Stop
Start
Start homing
Status
Referencing status
Tab. 234 Legend for homing to stop
4.4.3
Homing methods
The supported homing methods are oriented to the CANopen CiA 402 device profile for electric drives
and additionally manufacturer-specific methods.
Methods
Target and direction of homing travel are specified by the selected homing method.
Referencing methods with zero pulse detection and stop detection are not available in the open-loop
operation without encoder.
Example:
With method 2 "limit switch positive with zero pulse" the "limit switch" primary target is searched in
the positive direction at search velocity. Then the "zero pulse" secondary target is identified at creep
velocity in the negative direction. With travel to axis zero-point activated the parameterised axis zero-
point is approached at travel velocity.
The following homing methods are supported:
Method
No. (dec.)
Search direction
Primary target
Secondary target
37
—
Current position
—
34
1)
positive
Current position
Zero pulse
Current position
33
1)
negative
Current position
Zero pulse
18
positive
Limit switch
—
17
negative
Limit switch
—
2
1)
positive
Limit switch
Zero pulse
Limit switch
1
1)
negative
Limit switch
Zero pulse
Motion control
265
Festo — CMMT-ST-SW — 2019-02