ID Px.
Parameters
Description
Specifies the current lower limit value of the warning threshold
for the temperature monitoring of the power output stage.
Access
read/−
Update
effective immediately
9324
Current lower limit
value warning
threshold power out-
put stage temperat-
ure
Unit
°C
Specifies the current lower limit value of the temperature monit-
oring of the power output stage.
Access
read/−
Update
effective immediately
9325
Current lower limit
value power output
stage temperature
Unit
°C
Tab. 164 Parameters of “Temperature monitoring of the servo drive”
Diagnostic messages
No specific diagnostic messages are allocated to the function.
3.4.3.1
CiA 402
Objects of “Temperature monitoring of the servo drive”
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
920
0x2128.01
Temperature power output stage
FLOAT32
921
0x2128.02
Temperature status power output stage
SINT32
9314
0x2128.19
Upper limit value warning threshold power
output stage temperature
FLOAT32
9315
0x2128.1A
Upper limit value power output stage temper-
ature
FLOAT32
9316
0x2128.1B
Lower limit value warning threshold power
output stage temperature
FLOAT32
9317
0x2128.1C
Lower limit value power output stage temper-
ature
FLOAT32
9322
0x2128.21
Current upper limit value warning threshold
power output stage temperature
FLOAT32
9323
0x2128.22
Current upper limit value power output stage
temperature
FLOAT32
9324
0x2128.23
Current lower limit value warning threshold
power output stage temperature
FLOAT32
Product configuration