Value
Status
Description
0
Closed
The holding brake is closed
1
Open
The holding brake is open
2
Opened
The holding brake is being opened
3
Closed
Holding brake is being closed
Tab. 119 Holding brake status parameter values list
Diagnostic messages
No specific diagnostic messages are allocated to the function.
3.3.2.3
CiA 402
Holding brake objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
20
0x2150.01
Switch-on delay holding brake 1
FLOAT32
21
0x2150.02
Switch-off delay holding brake 1
FLOAT32
24
0x2150.05
Status holding brake 1
UINT32
29
0x2150.09
Selection of holding brake (manual opening)
UINT32
7162
0x216C.0F
Switch-on delay holding brake (user defined)
FLOAT32
7165
0x216C.10
Switch-off delay holding brake (user defined)
FLOAT32
7163
0x2162.12
Current switch-on delay holding brake
FLOAT32
7166
0x2162.13
Current switch-off delay holding brake
FLOAT32
7161
0x2106.2B
Switch-on delay holding brake
FLOAT32
7164
0x2106.2D
Switch-off delay holding brake
FLOAT32
40001
0x21A7.01
Activation current reduction holding brake
BOOL
40002
0x21A7.02
Delay time
FLOAT32
40003
0x21A7.03
Supply voltage holding brake
FLOAT32
40004
0x21A7.04
Holding voltage
FLOAT32
Tab. 120 Objects
3.3.3
Encoder configuration
3.3.3.1
Function
The Festo motor series has integrated encoders. If a Festo motor is used and the configuration is per-
formed with the device-specific plug-in, the required data for the encoder configuration is assumed
automatically in the project from the stored database with the selection of the motor.
The device has an encoder interface that supports different encoder protocols and standards.
Product configuration
152
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW