ID Px.
Parameters
Description
Specifies the nominal motor voltage of the motor -> data sheet
of the motor. An excessive DC link voltage can destroy the
motor!
Access
read/write
Update
reinitialization
71421
Nominal motor
voltage (user defined)
Unit
V
Determines the effective current that the motor requires to
apply the stall torque -> data sheet of the motor.
Access
read/write
Update
reinitialization
71424
Continuous current
(user defined)
Unit
Arms
The inductance is orthogonal to the direction of the field. This
value is a theoretical construct and cannot be measured -> data
sheet of the motor.
Access
read/write
Update
reinitialization
71430
Lq inductance (user
defined)
Unit
H
The inductance is in parallel with the direction of the field. This
value is a theoretical construct and cannot be measured -> data
sheet of the motor.
Access
read/write
Update
reinitialization
71431
Ld inductance (user
defined)
Unit
H
Selection of motor type -> data sheet of the motor.
–
1: stepper motor
–
2: servo motor (EC motor)
Access
read/write
Update
reinitialization
71432
Motor type
Unit
−
Tab. 104 Parameters
Value list of the temperature sensor parameters (settable using Px.7153)
Value
Temperature sensor
Description
0
Without temperature sensor
No temperature sensors available
Product configuration
131
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......