5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
81
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
607E
h
VAR
polarity
UINT8
rw
6093
h
ARRAY
position_factor
UINT32
rw
6094
h
ARRAY
velocity_encoder_factor
UINT32
rw
6097
h
ARRAY
acceleration_factor
UINT32
rw
Object 6093
h
: position_factor
The object position_factor converts all units of length of the application from position_units into the
internal unit increments (65536 increments correspond to 1 revolution). It consists of numerator and
denominator.
Motor
Gear unit
Axis
Motor with gearing
R
IN
R
OUT
x in positioning unit
(e.g. “mm”)
x in positioning unit
(e.g. “degrees”)
Fig. 5.3
Calculating the positioning units
Index
6093
h
Name
position_factor
Object Code
ARRAY
No. of Elements
2
Data Type
UINT32