7
Operating modes
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
207
Object 606D
h
: velocity_window
The object velocity_window is used to set the window comparator. It compares the actual speed value
with the prespecified final speed (object 60FF
h
: target_velocity). If the difference is less than specified
here for a certain period, the bit 10 target_reached is set in the object statusword.
also: object
606E
h
(velocity_window_time).
Index
606D
h
Name
velocity_window
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
speed units
Value Range
0 … 65536 min
-1
Default Value
4 min
-1
Object 606E
h
: velocity_window_time
The object velocity_window_time is used to set the window comparator along with the object 606D
h
:
velocity_window. The speed must lie within the velocity_window for the time specified here so that the
bit 10 target_reached is set in the object statusword.
Index
606E
h
Name
velocity_window_time
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
ms
Value Range
0 … 4999
Default Value
0