Object 605E
h
: fault_reaction_option_code
The object fault_reaction_option_code specifies how the motor controller behaves with an error (fault).
Since the error response in the CMMP series is dependent on the respective error, this object cannot be
parametrised and always returns 0. To change the error response of the individual errors
chapter
Index
605E
h
Name
fault_reaction_option_code
Object Code
VAR
Data Type
INT16
Access
rw
PDO Mapping
no
Units
–
Value Range
0
Default Value