![Festo CMMP-AS-***-M0 Series Manual Download Page 143](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119143.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
143
Object 6510
h
_A0
h
: drive_serial_number
The serial number of the controller can be read via the object drive_serial_number. This object serves
to achieve compatibility with earlier versions.
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
A0
h
Description
drive_serial_number
Data Type
UINT32
Access
ro
PDO mapping
no
Units
–
Value Range
–
Default Value
–
Object 6510
h
_A1
h
: drive_type
Through the object drive_type, the device type of the controller can be read. This object serves to
achieve compatibility with earlier versions.
Sub-Index
A1
h
Description
drive_type
Data Type
UINT32
Access
ro
PDO mapping
no
Units
–
Value Range
1018
h
_02
h
, product_code
Default Value
1018
h
_02
h
, product_code
Object 6510
h
_A9
h
: firmware_main_version
The main version number of the firmware (product stage) can be read out via the object
firmware_main_version.
Sub-Index
A9
h
Description
firmware_main_version
Data Type
UINT32
Access
ro
PDO mapping
no
Units
MMMMSSSS
h
(M: main version, S: sub version)
Value Range
–
Default Value
–