A. Technical specifications
102
Festo P.BE-CMMP-AS-3A-HW-EN 0708NH
A.1
Operation and display components
The CMMP-AS servo positioning controller has two LEDs on the front and one seven seg-
ment display for showing the operating status.
Component
Function
Seven segment display
Displays the operating mode and an error code should an error occur
LED1
Ready status
LED2
CAN bus status display
RESET button
Hardware reset for the processor
Table A.7 Display elements and RESET button
A.2
Power supply [X9]
Type CMMP-AS-C2-3A
Type CMMP-AS-C5-3A
Supply voltage
1 x 100 … 230 VAC [± 10%]
Frequency
50 … 60 Hz
Current consumption
3 … 2 A
6 … 4 A
Alternative DC supply
60 … 380 VDC
24 V supply
24 VDC [+6% -10%] (0.55 A) *)
24 VDC [+6% -10%] (0.65 A) *)
Intermediate circuit voltage with
active PFC (load independent)
360 … 380 VDC
*) plus the current consumption from holding brake and IOs, if present
Table A.8 Technical data: Power data [X9]
Note
With a warm motor and a supply voltage that is too low (outside
tolerance), the motor brake cannot open 100%, which can lead to
premature wearing of the brake.
Internal braking resistor
Type CMMP-AS-C2-3A
Type CMMP-AS-C5-3A
Internal braking resistor
165
110
Pulse power
1.1 kW
1.6 kW
Continuous power
10 W
20 W
Response threshold
440 V
440 V
Table A.9 Technical data: Internal braking resistor [X9]
External braking resistor
Type CMMP-AS-C2-3A
Type CMMP-AS-C5-3A
External braking resistor
100
80
Continuous power
250 W
500 W
Operating voltage
460 V
460 V
Summary of Contents for CMMP-AS-C2-3A