Ferroli Zefiro C11 User Manual Download Page 1

EN

ZEFIRO

Thank you for purchasing this product. 
The FERROLI instantaneous gas water heater you have chosen was designed and manufactured by our specialists 
and controlled in every stage according to the strictest quality standards, to meet your needs. 
To ensure best use of your new FERROLI instantaneous gas water heater, please read these instructions carefully. 

CONTENTS

DESCRIPTION, EQUIPMENT LEVELS

.................................................................................................. 3 

USER INSTRUCTIONS .............................................................................................................. ................ 5 

ELECTRONIC WATER HEATER ...................................................................................................................... 5

CONTROL PANEL.................................................................................................................. .................... 6 
INSTALLER INSTRUCTIONS ......................................................................................................... .........6 

PLACE OF INSTALLATION............................................................................................................................... 6 
GAS AND WATER CONNECTIONS ................................................................................................................. 6 
WALL MOUNTING............................................................................................................................................. 7 
MAIN DIMENSIONS .......................................................................................................................................... 7 
FLUE GAS EXHAUST ....................................................................................................................................... 8 
EXTERNAL CASING ASSE MBLY..................................................................................................................... 8 
CHECK AND DELIVERY ................................................................................................................................... 8 
FUME EXHAUST SAFETY DEVICE ................................................................................................................  8 
TECHNICAL DATA ............................................................................................................................................ 9 

SERVICE AND MAINTENANCE........................................................................................................ ....10
CONVERSION ..................................................................................................................... ...................... 10
WIRING DIAGRAM ................................................................................................................. ................ 11 

Summary of Contents for Zefiro C11

Page 1: ...your new FERROLI instantaneous gas water heater please read these instructions carefully CONTENTS DESCRIPTION EQUIPMENT LEVELS 3 USER INSTRUCTIONS 5 ELECTRONIC WATER HEATER 5 CONTROL PANEL 6 INSTALLER...

Page 2: ...d with an electric system allowing the gas to come out the burners only in safe conditions presence of ame 6 Power adjustment knob for manually setting the required power 7 Temperature selector for se...

Page 3: ...EN ZEFIRO 4 5 B D C L A4 M Ze ro C11 560 550 170 328 110 170 Ze ro C14 660 650 220 400 130 220 1 Hot water outlet R 1 2 2 Gas inlet R 1 2 3 Cold water inlet R 1 2...

Page 4: ...ps if the ame does not light after a few seconds Therefore it is necessary to eliminate the cause or the element preventing the gas from reaching the water heater e g inadvertent closing of the gas co...

Page 5: ...rmal operation and the evacuation of fumes Also the fumes forming under these conditions are extremely harmful to health if dispersed in the domestic environment Therefore the place of installation mu...

Page 6: ...shown in the gure below 3 2 Mark the position of the bottom screws 3 3 Hang the water heater on the plugs hooks and tighten the screws for xing the unit to the wall 3 4 Connect the hot and cold water...

Page 7: ...each model and CHECK ITS CORRECT OPERATION leaving it on for 15 minutes 6 4 For correct tting of the temperature selector knob make the pointer match the last curved section on the right of the picto...

Page 8: ...as inlet pressure G20 Mbar 20 0 20 0 Max gas ow rate G20 m 2 23 2 83 Min gas ow rate G20 m 0 86 1 13 Burner injectors G31 n x 10 x 0 72 16 x 0 66 Gas inlet pressure G31 Mbar 37 0 37 0 Max gas ow rate...

Page 9: ...the current regulations such as those of the Local After Sales Technical Service FERROLI declines any liability for damage or injury caused by unquali ed and unauthorised people tampering with the uni...

Page 10: ...EN ZEFIRO 11 WIRING DIAGRAM...

Page 11: ...FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it...

Reviews: