49
EN
Cod. 3541T090 - Rev. 00 - 06/2019
REMOTE CONTROLLER - FOR SERVICEMAN MENU
8. REMOTE CONTROLLER - FOR SERVICEMAN MENU
8.1 How to go to FOR SERVICEMAN
See
“CONTROLLORE REMOTO DEL SISTEMA”
Go to MENU> FOR SERVICEMAN. Press OK
FOR SERVICEMAN
Please input the password:
ADJUST
SCROLL
ENTER
OK
0
0 0
fig. 100 -
The password is 666 or 234. Use ◄ ► to navigate and use ▼ ▲ to adjust the
numerical value. Press OK. The following page is displayed:
Use ▼ ▲ to scroll and use “ok” to enter submenu for setting the parameters.
FOR SERVICEMAN
2. COOL MODE SETTING
3. HEAT MODE SETTING
4. AUTO MODE SETTING
5. TEMP.TYPE SETTING
6. ROOM THERMOSTAT
7. OTHER HEATING SOURCE
1. DHW MODE SETTING
SCROLL
ENTER
OK
FOR SERVICEMAN
9. SERVICE CALL SETTING
10. INITALIZE MANUALLY
11. TEST RUN
12. SPECIAL FUNCTION
13. AUTO RESTART
8. HOLIDAY AWAY MODE SETTING
SCROLL
ENTER
OK
fig. 101 -
☞
NOTE
ON/OFF
by digital input or switch (refer to
room thermostat
).
COOL/HEAT
mode managment by digital input (refer to
room thermostat
).
Description of terms
The terms related to this unit are shown in the table below
ID
Description
T1
Water temperature leaving the heat exchanger plate heat exchanger
T1B
Water temperature sent to the system
T1S
Target outlet water temperature
T2
Temperature of refrigerant at outlet/inlet of plate heat exchanger when in heat mode/cool mode
T2B
Temperature of refrigerant at inlet/outlet of plate heat exchanger when in heat mode/cool mode
T3
Temperature of tube at outlet/inlet of condenser when in cool/heat mode
T4
Outdoor air temperature
T5 (not used)
Temperature of domestic hot water (misured by the temperature probe installed on the DHW tank)
Th
Refrigerant suction temperature
Tp
Refrigerant discharge temperature
TW_in
Inlet water temperature of plate heat exchanger
TW_out
Outlet water temperature of plate heat exchanger
AHS
Boiler
IBH1 (not used)
The first stage of the backup heater (if installed)
IBH2 (not used)
The second stage of the backup heater (if installed)
TBH (not used)
Backup heater in the domestic hot water tank (if installed)
Pe
Refrigerant evaporate/condense pressure in cool/heat mode
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...