INSTALLATION
POWER IN
Method B
H
RT
L1 C
fig. 40 -
External COOL/HEAT (thermostat)
Voltage
220-240VAC
Maximum running current
0.2A
Wiring size
0.75mm
2
HEAT
COOL
POWER IN
Method A
H
RT
L1 C
fig. 41 -
Method
ON/OFF Heat / COOL
Digital input effect
Remote controller
Setup*
A
√
The operation mode is defined by the digital input.
The unit will be ON in COOL mode when L1-C is closed.
The unit will be ON in HEAT mode when H-L1 is closed.
If both digital input are closed the unit will be ON in COOL mode.
The user can only set the
target water flow temp.
6 ROOM THERMOSTAT
ROOM THERMOSTAT
MODE SETTING
DUAL ROOM
THERMOSTAT
SCROLL
YES
NON
YES
NON
YES
NON
6 ROOM THERMOSTAT
ROOM THERMOSTAT
MODE SETTING
DUAL ROOM
THERMOSTAT
SCROLL
YES
NON
YES
NON
YES
NON
B
√
The unit will be ON when the digital input is closed.
The unit will operate in the mode defined by the controller.
The user can set the ope-
ration mode and the target
water flow temp.
6 ROOM THERMOSTAT
ROOM THERMOSTAT
MODE SETTING
DUAL ROOM
THERMOSTAT
SCROLL
YES
NON
YES
NON
YES
NON
6 ROOM THERMOSTAT
ROOM THERMOSTAT
MODE SETTING
DUAL ROOM
THERMOSTAT
SCROLL
YES
NON
YES
NON
YES
NON
☞
NOTE: For more details refer to paragraph “ ROOM THERMOSTAT
(for more details refer to paragraph “8.8 Room thermostat (ON/OFF - HEAT/COOL by
.
Boiler (AHS)
Connection already made at the factory.
TERMINAL BOILER
(terminals 5 and 6 see “fig. 206 -”)
AHS1 AHS2
fig. 42 -
Outside circulation pump (P_o)
P_o outside pump
P_o
N
fig. 43 -
Voltage
220-240VAC
Maximum running current
0.2A
Spessore cablaggio
0.75mm
2
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...