The connecting kits shown in fig. 6 are supplied as standard.
Key
A =
Nut
B =
Compression olive
D =
3/4” seal (green)
E =
1/2” seal (green)
F =
1/2” gas seal (blue)
G =
Filter
H =
Cap
Flow isolation valve
Hot water connection
Gas isolation valve
Cold water isolation valve
Return isolation valve
Ø22
Ø22
Ø22
Ø15
Ø15
A
A
A
A
A
B
B
B
B
B
D
D
E
E
F
G
H
fig. 6
Water treatment
When treatment is used ferroli limited only recommend the use of proprietary Brand, such as Fernox
or Sentinel water treatment products, which must be used in accordance with the manufactures
instructions. for further information contact:
Feronx
Manufacturing
Co.
LTD. Sentinel
Division
Tandern house, Marlowe Way
Betz Dearborn LTD
Croydon, surrey, CRO 4YS
Widnes, Cheshire WA8 8ND
Tel: 0870 5601 5000
Tel: 0151 424 5351
Note
- When the boiler is installed with an existing or new system any unsuitable additives or system debris
must be removed by thorough cleansing. All systems should be cleansed according to B.S. 7593.
Note
- In hard water areas treatment to prevent lime scale may be necessary.
Note
- It is important that the correct concentration of the water treatment product is maintained in
accordance with the manufacturers instructions.