Fern-Howard FHL414 Setup Instructions Download Page 1

FHL414

 Set-up Configuration - Micro Sensor

Fern-Howard luminaires can come with 3 different types of micro-sensor controllers. Please determine which 
micro-sensor your luminaire has (Type 1, 2 or 3) and follow the relevant set-up instructions below.

For more Information call 

01420 470 400

 email 

[email protected]

 or visit 

www.fernhoward.com

Type 1

 

Type 2

 

Detection Sensitivity:

This determines the effective range of 
the motion detector and is set by DIP 
switches on the sensor itself. Note 
that reducing the sensitivity will also 
narrow the detection range.

Sensor Sensitivity:

Adjustable ‘-’ approx. 2M to ‘+’ approx 10M

Meter

Time

Lux

The following settings are available:
I  -  maximum range up to 5m
II  -  range up to 3.5m
III  -  range up to 2m
IV  -  range up to 1.5m
V  -  range up to 1m

The following settings are available:
I  -  2 Lux darkness operation only
II  -  5 Lux darkness operation only
III  -  20 Lux twilight operation
IV  -  30 Lux twilight operation
V  -  daylight, daylight sensor   
    operation disabled

Hold Time:

This determines the length of time 
the lamp is held on after movement is 
detected and is set by DIP switches. 
The walk test setting is useful when 
installing the fitting to establish 
correct operation and range.

Delay off Time:

5 sec to 30 min range and Test mode

Daylight Sensor:

This setting holds the lamp off should 
there be sufficient daylight and is set 
using DIP switches on the sensor.

IMPORTANT NOTE: When a setting change on a micro-sensor has been 
made, the luminaire must be power cycled for the change to take effect.

Ambient Light Override:

Approx. 5 Lux to 
5 Lux - sensor module can work at dark status only  
 

- sensor module can work at any light level

30m

Test

5s

5m

15m

5

100

500

10M

3M

2.5M

The following settings are available:
I  -  Walk test mode 5s
II - 30s
III  -  3 minutes
IV  -  5 minutes
V  -  15 minutes
VI  -  25 minutes

Detection Area

Detection Area

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

Adjustable Detection Area

Hold Time

Hold Time

Adjustable Detection Area

Daylight Threshold

Daylight Threshold

Daylight Sensor

Daylight Sensor wire remote

Max 200W

Reviews: